f) Before starting using the device, ensure that all the screws havce been tighted.
g) For outdoor use (IPX4-Anti-splash: ).
e) Before installation and maintenance please ensure that the power supply is switched off to
avoid an electric shock.
d) The lighting is a product of protection class I and must be connected to a protective earthing.
to the one indicated on the label.
Read this manual carefully before using this product and check whether there are any damaged
parts. The product cannot be installed in case of damages. Keep this manual for further reference.
SAFETY WARNINGS:
a) Keep this product out of reach of children and unauthorized users.
GB
07
I
08
EXPLANATION OF SYMBOLS:
Conforms to relevant European requirements for the product.
The crossed-out wheeled bin symbol indicates that the item should be disposed of
separately from household waste. The item should be handed in for recycling in
accordance with local environmental regulations for waste disposal. By separating a
marked item from household waste, you will help reduce the volume of waste sent to
incinerators or land-fills and minimize any potential negative impact on human health
and the environment.
TECHINICAL DATA:
i) If the glass is broekn, replace it immediately.
0201
220-240 V ~ 50 Hz
Max. 500 W
IP54
R7s 400 W / 118 mm
0,87 kg
H05RN-F 3G 1,0mm² (not included)
177 x 140 x 5 mm
Type
Rated voltage
Rated power
IP Level
Cable
Lamp
Weight
Floodlight
Dimension of
protective glass
j) Minimum distance from lighted objects 1 m.
INSTALLATION OF THE BULB:
a) Before installing bulb, please make sure the plug is not connected to the socket.
b) Loose the upper scres from the light guard and open it.
c) Take the bulb our of it’s packaging. Do not touch the bulb with bare hand. Use a towel
to fix the bulb into the fitting.
First press one side of the fitting against the metal pin and shift
rds so that you can press the other
side of the bulb against the metail pin.
d) After chanding the light bulb, please pay attention to the correct positioning of the seal gasket.
e) Fix the light guard by tightening the screw. Do not over tighten which may damage the glass.
the pin backwa
Fig . 1
Fig . 2
Fig
.
3
53mm
0102B
70mm
0202B
2xØ9mm
2xØ5mm
Ø11mm
Ø7mm
b) The installtion must be performed by qualified electrican.
c) Before connecting the appliance for the first time, check whether your voltage corresponds
h) The product must not be used if the safety glass is not proprely attached.
k) Not suitable for heavy use.
INSTALLATION:
Note: This appliance is only intended for fixed installation. Follow the instructions in fig. 1.
Do not install this unit to the ceiling. Do not attach to a Stud. Do not attach to a surface subject to
vibrations. The halogen bulb in the housing would burn out prematurely if the housing installed
at an angle more than 4° .
2. Pull the cable through the gasket hole. Check carefully whether the sealing opening in good
condition is.
3. Connect the wires according fig. 2.
4. Check carefully whether the strain relief properly and use them appropriately.
5. Fix the cover by tightening to the junction box.
6. Fasten the floodlight with screws and bolts in the desired position. (Fig. 3)
1. Turn off the power before installing.
V190522