background image

Maintenance 

31

 

be extended. All repairs or replacements performed by Seller pursuant to these 
Warranty Provisions shall be performed at one of the Seller’s facility in 
Allentown, Pennsylvania, U.S.A. or at the facility of an authorized representative 
of Seller, which location shall be determined by Seller in its sole discretion; 
provided, however, that Seller may, in its sole discretion perform such repairs or 
replacements at Buyer’s facility in which case Buyer shall pay Seller’s travel, 
living and related expenses incurred by Seller in performing the repairs or 
replacements at Buyer’s facility. As a condition precedent to Seller’s obligation 
to repair or replace a product part under the Initial Warranty, Buyer shall 
(i)promptly notify Seller in writing of any such defect; (ii) shall have returned the 
product’s record of purchase to Seller or to Seller’s authorized representatives 
within thirty (30) days of the date the product is shipped by the seller; and (iii) 
assist Seller in all respects in its attempts to determine the legitimacy and basis 
of any claims made by or on behalf of Buyer including but not limited to 
providing Seller with access to the product to check operating conditions. If 
Buyer does not provide such written notice to Seller within the Initial Warranty 
period or fails to return the product’s record of purchase as set forth above, 
Seller shall have no further liability or obligation to Buyer therefor. In no event 
shall Seller’s liability under the Initial Warranty exceed the original purchase 
price of the product which is the subject of the alleged defect. 
 
THE REMEDIES PROVIDED IN THE INITIAL WARRANTY ARE THE SOLE AND 
EXCLUSIVE REMEDIES AVAILABLE TO THE BUYER. NOTWITHSTANDING 
ANYTHING TO THE CONTRARY CONTAINED HEREIN, AND EVEN IF THE SOLE 
AND EXCLUSIVE REMEDIES FAIL OF THEIR ESSENTIAL PURPOSE FOR ANY 
REASON WHATSOEVER, IN NO EVENT SHALL SELLER BE LIABLE FOR BUYER’S 
MANUFACTURING COSTS, LOST PROFITS, GOODWILL, OR ANY OTHER SPECIAL, 
INDIRECT, PUNITIVE, INCIDENTAL OR CONSEQUENTIAL DAMAGES TO BUYER 
OR ANY THIRD PARTY AND ALL SUCH DAMAGES ARE HEREBY DISCLAIMED. 
 

Assignment 

Buyer shall not assign any of its rights or obligations hereunder without the 
prior written approval of Seller; provided, however, that if Buyer is a distributor 
of Seller, the rights and obligations of Buyer under these Warranty Provisions 
shall inure to the benefit of and be binding upon Buyer’s customers who provide 
the product’s proof of purchase to Seller pursuant to the terms set forth herein. 
Seller may assign any or all of its rights or obligations hereunder without Buyer’s 
prior consent. 
 

Governing Law 

The Warranty Provisions and all questions relating to their validity, 
interpretation, performance, and enforcement shall be construed in accordance 
with, and shall be governed by, the substantive laws of the Commonwealth of 
Pennsylvania without regard to its principles of conflicts of law.

 

 

Содержание Corio C

Страница 1: ...Heating immersion circulator open bath heating circulator refrigerated circulator Original operating manual 1 950 0400 us V04 03 2022...

Страница 2: ...nt of this operating manual is protected by copyright Information including texts images and other contents may not be reproduced distributed transmitted stored or otherwise used in any form without p...

Страница 3: ...13 5 2 Operating and functional elements 14 5 2 1 Key description 15 5 3 Alarm messages 15 5 4 Technical data 16 5 4 1 Material of parts that come into contact with the medium 18 5 4 2 Bath fluids 18...

Страница 4: ...he low liquid level safety function 27 9 3 Replace detachable power cord 27 9 4 Emptying 28 9 5 Clean device 28 9 6 Device storage 29 9 7 Technical Service 29 9 8 Warranty 30 10 Disposal 33 10 1 Devic...

Страница 5: ...ent choice JULABO would like to thank you for the trust you have placed in our company and products This operating manual will help you become acquainted with the use of our units Read the operating m...

Страница 6: ...e directly from JULABO or your specialist dealer Please note that JULABO cannot provide a warranty service if non original JULABO spare parts are used 2 2 Accessories JULABO offers a wide range of acc...

Страница 7: ...serious injuries NOTE This signal word designates a possibly harmful situation If it is not avoided the system or objects in its vicinity may be damaged 2 4 Symbols used Various symbols are used throu...

Страница 8: ...in suitable tanks can be temperature controlled These devices are not suitable for direct temperature control applications for food other consumables or pharmaceutical or other medical products Do not...

Страница 9: ...the device The operator must ensure that the device is checked for safety and functionality at regular and usage related intervals The operator must ensure that the mains supply has a low impedance t...

Страница 10: ...evice operation These Safety Instructions must be followed to ensure safe operation Vapors may escape during the temperature control application Operate the device in a well ventilated location If fla...

Страница 11: ...Safety function Technical protective devices provide for safe operation If a safety function is triggered the operator is alerted with a message on the display and an acoustic signal Overheating prot...

Страница 12: ...it has a warning system to prevent overheating of the heater or dry running of the pump The low liquid level alarm is triggered when the float reaches its lower limit stop The device switches off the...

Страница 13: ...arious baths with volumes of up to 30 l Depending on the device combination and accessories used the circulators work in a temperature range from 20 C to 100 C Heating immersion circulator Open heatin...

Страница 14: ...igure shows the operating and functional elements and their position on the unit Fig 1 Control and function elements 1 Mains switch 2 Heating control LED 3 LED display 4 Alarm control LED 5 Keypad wit...

Страница 15: ...are unable to rectify a fault contact Technical Service Alarm In the event of an alarm the control LED lights up The temperature control is stopped At the same time a continuous acoustic signal sound...

Страница 16: ...nection to a separate power transformer or generator Connection to a low voltage line is not permitted In accordance with IEC 61010 1 the device is designed for safe operation under the following ambi...

Страница 17: ...nsor adjustment 1 point adjustment Pump Volume flow rate at 0 bar l min 6 Supply pressure at 0 l bar 0 1 Maximum viscosity cSt 1 Dimensions Dimensions W x D x H cm 13 2 x 16 0 x 36 2 Immersion depth c...

Страница 18: ...perature sensor 1 4301 Float 1 4401 Float pipe 1 4571 Hose olive 1 4301 Single ear clamp 1 4301 Hose FPM FKM 5 4 2 Bath fluids Only water with an electrical conductivity of 0 1 to 50 S is permitted as...

Страница 19: ...Product description 19 Water as bath fluid Water can be used for working temperatures from 5 C to 90 C Only use ultra pure water or distilled water with the addition of 0 1 mg Na2CO3 per liter...

Страница 20: ...vice has been switched off and may cause burns if touched Allow the device to cool down to room temperature after switching off Wear protective gloves The device is switched off and cooled to room tem...

Страница 21: ...er cable The circulator is connected 7 2 Fill device This section describes how the device should be filled with bath fluid during initial operation Specifications for filling volume can be found in t...

Страница 22: ...ration 22 Once the working temperature has been reached and the sample inserted the bath fluid level in the bath tank should cover the heating coil of the heating circulator The unit is filled with ba...

Страница 23: ...switched off 8 3 Configuring setpoint temperature Device is running the temperature control application to the configured setpoint temperature The factory setting is 10 C The setpoint temperature can...

Страница 24: ...t possible to start a temperature control application directly using the mains switch or via an intermediate timer The device is configured ex works in such a ways that it switches to a safe operating...

Страница 25: ...temperature control application from 0 to 999 minutes The setpoint temperature is maintained for the programmed time After the set duration has elapsed the device switches to standby mode The unit is...

Страница 26: ...th tank between the temperature sensor and a defined more remote point within the bath fluid volume As a result the measured temperature deviates slightly from the actual bath temperature Adjustment o...

Страница 27: ...long object e g a straightedge carefully push the circulator float downwards until it reaches its mechanical stop An acoustic signal sounds and the error code E 01 is displayed The low liquid level sa...

Страница 28: ...ive gloves The device is switched off and disconnected from the mains voltage 1 Remove the sample from the bath 2 Remove the circulator from the bath 3 Tilt the bath over a sink The device is emptied...

Страница 29: ...onents completely 2 Clean the device 3 Carefully dry the device and all its system components e g with compressed air 4 Close all connections 5 Store the device in a dust free dry and frost free locat...

Страница 30: ...not include damage to the product resulting from accident misuse improper installation or operation unauthorized or improper repair replacement or alteration including but not limited to repairs repl...

Страница 31: ...th above Seller shall have no further liability or obligation to Buyer therefor In no event shall Seller s liability under the Initial Warranty exceed the original purchase price of the product which...

Страница 32: ...to any other provision of the Warranty Provisions nor as to any prior or subsequent breach of the same provision Freight Seller will arrange and pay for shipping and handling for the return of the un...

Страница 33: ...ect all power cables and if necessary data cables from the circulator and from other connected devices 3 If present disconnect the circulator combination from a connected external application 4 Remove...

Страница 34: ...ature difference between the working temperature sensor and the high temperature protection sensor is too large Increase pump capacity If the fault has not been remedied contact Technical Service 14 T...

Страница 35: ...power consumption via USB interface Check inserted USB stick for errors and replace if necessary The USB A interface is not suitable for storage media with a power consumption of 300 mA 108 Alarm lat...

Страница 36: ......

Отзывы: