Installation in a plasterboard wall
Figure 1
For extra security, install a 10 mm thick sheet of Minerit board or Masterboard behind the fire (see
figure 1).
The dimensions of the screws should be: 70 mm long and 5 mm in diameter.
The screws must be fastened 45 mm into the studs through the Minerit board.
The screws must be able to carry a minimum load of 50 kg/screw.
After installing the wall fire, position and screw in the enclosed angle piece close to the upper edge
of the fire so that it cannot be lifted off.
Installation in a brick or concrete wall
Hang the fire on a steel expander as shown.
The expander must be fastened at least 50 mm into a solid wall (excluding any plaster).
The screws must be able to carry a minimum load of 50 kg/screw.
After installing the wall fire, position and screw in the enclosed angle piece close to the upper edge
of the fire so that it cannot be lifted off.