EN
30
lack experience or knowledge,
if they are supervised or
receive instructions concerning
the safe use of the appliance
and understand the risks
involved. Keep children under
supervision to make sure they
do not play with the appliance.
Do not allow children to use,
clean or maintain the
appliance without supervision.
IMPORTANT:
• Some parts of the appliance
get very hot – risk of burn
injuries. Keep the appliance
under careful supervision
when it is used by, or near
children or persons with
functional disorders.
• Do not cover the appliance
– fire risk.
• Never do a leakage test with
a naked flame.
Symbols
Do not cover the gas stove.
WARNING: Hot surfaces.
Fire risk.
Ventilate the area where the
stove has been placed at
regular intervals when it is on.
Do not use the stove when you
are sleeping.
Approved as per
applicable directives.
TECHNICAL DATA
Gas category
I3B/P(30) / I3B/P(37)
Gas pressure
28-30 mbar/37 mbar
Gas type
G30, G31
Destination countries
S/N/PL
Injector size
0.58 mm / 0.55 mm
Gas heater output
1.5/2.8/4.1 kW
Gas consumption
109/204/298 g/h
Lighter system
Piezo electric
Type of cylinder
Up to 15 kg
Gas hose
Approved in accordance with EN standard
Gas regulator
Approved as per EN16129 (max flow 1.5 kg/h)
Weight
5.8 kg
DESCRIPTION
1. Gas valve
2. Gas tap
3. Hose
4. Gas regulator
5. Cover plate
6. Gas cylinder
FIG. 1