58
−
@9
#0
#1
#2
#4
#5
#3
1 mm
Adjustment Procedures
Results of Improper Adjustment
™
Make adjustment by loosening the screw inside
@9
so that
@9
is mounted around the intermediate point between 2 holes for
the hook of lifter lever.
™
Adjust the lifting amount of presser foot by turning the cylinder
rod
#2
loosening the rod end nut
#1
. (If the cylinder rod becomes
too small to turn remove the collar
#0
.)
™
Make adjustment by loosening the nut
#3
and turning the screw
#4
so that the clearance between the hinge screw
#5
and the
top end of screw is to be around 1 mm when the presser foot
goes down.
™
Too short stroke could cause the
insufficient lifting amount.
™
Too large stroke could cause the
breakage of the spreader,
needle clamp and thread guide.
™
No clearance made between the
hinge screw and stopper screw
could cause the presser foot
floating.
Presser foot lifting lever
Old type
From
the
library
of:
Diamond
Needle
Corp