51
−
A
2) Adjustment of the right position of movable knife (return)
Space between lower knife
7
and lever
8
is to be 0.4 mm
1) Stroke adjustment (common to both elctromagnetic and pneumatic type)
Stroke A
17mm : Gauge 4.8mm or less
18mm : Gauge 5.6mm or more
(4) Thread trimmer device (MFC)
Standard Adjustment
0.4 mm
7
8
From