![JUKI Union Special MFC-7406 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/juki/union-special-mfc-7406/union-special-mfc-7406_engineers-manual_2029560022.webp)
−
19
−
MF
Standard Adjustment
10) Looper thread cam
1
Timing
™
When the looper thread is pulled from the highest point of the looper thread cam, the top point of
the left needle aligns with the lower face of the looper.
3
Position of thread guide and auxiliary thread tension
™
The position of the thread guide is to be set at the position that the looper thread just becomes tight
when the looper is in the extreme left.
™
Adjust the tension of the auxiliary thread tension to make as low as the thread is just stabilized.
2
Position of looper thread guide plate and looper thread cam pawl wire
™
The height of the looper thread guide plate is 1.6 mm from the lowest part of the looper cam to the
upper part of the looper thread guide plate.
™
The rear side of the looper thread cam pawl touches the wire, and its front side is 9.6 mm above
the upper face of the wire at the highest place of the inside.
™
The looper thread cam pawl and wire are to be positioned in the center of the looper thread cam
plate.
Back of
looper
Align with lower
face of looper
Needle
descends
Looper
thread
#9
Looper thread cam
9.6 mm
1.6 mm
Looper thread
guide plate
Touch
Wire
Looper thread cam
Looper thread cam pawl
Auxiliary thread
tension
Looper thread
cam
Wire
Thread guide
Looper thread
guide plate
In the center
From
the
library
of:
Diamond
Needle
Corp