77
(1) Overlapped stitching
■
Overlapped stitching setting screen
Example) Standard zigzag
■
Sewing shape setting screen
1) Select
showing overlapped stitching with
1
of sewing shape setting screen.
2) Press
to display overlapped stitching setting screen.
3) Set the number of stitches and number of processes of the respective processes in the overlapped stitching
setting screen
2
: Set the number of stitches of process A with “+” and “–”. 0 to 19 stitches for the number of stitches of
section A can be set.
3
: Set the number of stitches of process B with “+” and “–”. 0 to 19 stitches for the number of stitches of
section B can be set.
4
: Set the number of stitches of process C with “+” and “–”. 0 to 19 stitches for the number of stitches of
section C can be set.
5
: Set the number of processes with “+” and “–”. 0 to 9 times for the number of processes can be set.
4) By performing depressing the front part of the pedal, the sewing machine repeats the specified number of
times of normal and reverse feed stitching, performs automatic thread trimming and stops.
* Turn ON the thread trimming prohibition switch ON when you desire to stop the sewing machine with
needle UP position without performing thread trimming after all processes have been completed.
* Thread trimming is performed at any occasion in case of one-shot stitching and the last of process. The
one-shot stitching cannot be turned OFF.
(2) Programmed stitching
■
Programmed stitching
Programmed stitching can program the constant-dimension stitching process up to 20 steps and set the number
of stitches to each step up to 500 stitches.
* For the programmed stitching, the pattern registration cannot be performed.
2 3 4 5
2 3 4 5
6-9. Selection of the kind of stitching
Select the kind of stitching
from among free stitching ,
overlapped stitching and
programmed stitching .
Press switch
1
of sewing
shape setting screen to select
the kind.
Standard delivery level of the key lock is “1”. When the level of the key lock is the case
other than “0”, be sure to change the level to “0” to perform the operation below.
Impor tant
1