86
5
optional switch function selection (Function setting No.12 SW 2) : It is used only when it is
combined with the machine head provided with the optional switch.
(optional SW kit Part No. : 40003640)
Functons to be assgned to the optonal swtch can be selected from the followng functons.
0 : No functon (Standard settng)
1 : Needle up / down compensatng sttchng : Every tme the swtch s pressed, normal feed
sttchng by half sttch s performed. (Same operaton as that of up/down compensatng
sttchng swtch on the panel.)
2 : No functon
3 : No functon
4 : Thread trmmng functon : Ths functon s actuated as the thread trmmng swtch.
5 : Presser foot lftng functon : Ths functon s actuated as the foot lfter swtch.
6 : One sttch compensatng sttch : Every tme the swtch s pressed, one sttch sttchng
operaton s executed.
7 : No functon
8 : Pedal neutral presser lftng functon selecton
Do not set to 2, 3, and 7. If these numbers are set, trouble or accdent wll be caused.
6
Neutral automatic presser lifting function (with AK device only) (Function setting No.21 N-NPL)
Ths functon can automatcally lft the presser foot when the pedal s n the neutral poston.
Automatc lftng tme of the pedal depends on the automatc lftng tme after thread trmmng and when
the presser foot s automatcally lowered, t s automatcally lfted at the second neutral poston after t has
come off the neutral poston once.
0 : off
Functon of neutral automatc presser lftng s not operatve.
1 : on
Selecton of functon of neutral automatc presser lftng
7
Function of changeover of needle up/down compensating switch on the operation panel function
(Function setting No. 22 F-CMSP)
Functon of needle up/down compensatng swtch on the panel of IP-110 can be changed over to needle
up/down compensatng sttchng or one sttch compensatng sttchng.
0 : Needle up/down compensatng sttchng
1 : One sttch compensatng sttchng
optional SW
optional SW
A. In case of the machine with the auxiliary
thread take-up lever
B. In case of the machine without the auxiliary
thread take-up lever