– 67 –
1. When the moving knife
stays in the initial position, loosen the
clamp spring setscrew
.
(When removing the clamp spring setscrew
completely, move the
moving knife
manually. While the hand wheel is turned by hand,
the moving knife
can be moved after passing the position of the
engrave line L.)
2. Adjust the distance to 43.0 to 43.5mm between the clamp spring
and the bed end.
(At that time, it is possible to use an accessory adjusting gauge.)
3. Let the clamp spring
come in contact with the moving knife
and tighten the clamp spring setscrew
.
(Tightening torque: 0.2 to 0.3N•m (2 to 3kgf•cm))
* When using an optional clamp spring
for thin threads, the
adjusted value shall be 43.5mm so that the clamp spring
is
made to contact the side surface of the moving knife
strongly.
[Confirmation]
Examine the following two points when the clamp spring
is
mounted:
1. No contact between the clamp spring
and the hook
2. No contact with the clamp spring
when the moving knife
has advanced to the extreme far end
* If positioning for the clamp spring
cannot be adjusted by
loosening the clamp spring setscrew
, try to loosen the clamp
spring base setscrew
and move the clamp spring base
for
adjustments.
(Vertical positioning for the clamp spring base
is devised
based on the attachment to the hook shaft base. Lightly pressing
it downwards, tighten the setscrew
.)
Adjustment Procedure
Results of Improper Adjustment
2.4
43.0
(t = 0.6)
29.0
26.8
37.8
9.0
Adjusting gauge (accessory)