66
−
9) ACTVR function (Memory switch No. 17)
This function is used when performing fine adjudstment of tension at parallel section or bar-tacking
section using the optional tension variable resistor.
0 : Ineffective
1 : Effective
Range of fine adjustment
Tension at parallel section
:
±
50 for the set value on the panel
Tension at bar-tacking section
:
±
20 for the set value on the panel
When fine adjustment cannot be performed with the variable resistor, change the set value on the
panel.
Caution : If you make the setting effective without connecting the variable resistor, the tension becomes
improper. Do not make the setting effective when the variable resistor is not connected.
10) Function switch setting (Memory switch No. 18)
This switch sets the data No. which is selected with “F” key on the panel.
It is convenient to register the data No. which is often used.
Data No. 13 “Basting” is set for the initial setting.
11) Reinforcement stitching of radial shape function (Memory switch No. 19)
This switch can perform setting of reinforcement stitching in lateral direction before sewing the radial
section when selecting the radial shape in the data No. 10.
0 : Without reinforcement stitching
1 : With reinforcement stitching
Reinforcement
stitching
1
7
0
1
8
1
3
1
9
0