19
−
Adjustment Procedures
Results of Improper Adjustment
Adjust and fix with screws
2
so that starting sensor plate
1
enters in the center of the detecting section of starting sensor
5
when the starting has functioned. The dimension from starting
sensor
5
to the bottom end of starting sensor plate
1
is 1 to 3
mm.
Caution : Make sure that starting sensor plate
1
does not
come in contact with starting sensor
5
when
starting has functioned.
In addition, do not perform the adjustment of the
position of the sensor with starting safety
solenoid base
3
since the play of starting safety
lever
4
is adjusted with starting safety solenoid
base
3
.