JUKI KE-2070 Скачать руководство пользователя страница 4

            KE-2070/2080 MS 

Parameter                                   

[1]

 

Overview ..................................................................................................1-1

 

1-1.

 

Definition ..................................................................................................................1-1

 

1-2.

 

Starting up and exiting the MS parameter ................................................................1-1

 

1-3.

 

Configuration............................................................................................................1-4

 

1-4.

 

MS parameter storage locations...............................................................................1-5

 

1-5.

 

Basic operation.......................................................................................................1-14

 

[2]

 

Control menu ...........................................................................................2-1

 

2-1.

 

Start up.....................................................................................................................2-1

 

2-2.

 

Menu contents..........................................................................................................2-1

 

2-3.

 

XY move...................................................................................................................2-2

 

2-4.

 

Z move .....................................................................................................................2-3

 

2-5.

 

Conveyor control ......................................................................................................2-4

 

2-6.

 

Light map .................................................................................................................2-4

 

2-7.

 

Light setting..............................................................................................................2-5

 

2-8.

 

Nozzle up cylinder ....................................................................................................2-5

 

[3]

 

Initial set-up..............................................................................................3-1

 

3-1.

 

Machine specifications .............................................................................................3-1

 

3-2

 

Square adjustment ...................................................................................................3-2

 

3-3.

 

Origin rough adjustment ...........................................................................................3-5

 

3-4.

 

XY axis correction coefficient ...................................................................................3-6

 

3-5.

 

Options.....................................................................................................................3-7

 

3-6.

 

Action specifications.................................................................................................3-9

 

3-7.

 

X axis curve correction ...........................................................................................3-14

 

3-8.

 

Comment................................................................................................................3-15

 

[4]

 

Offset set-up ............................................................................................4-1

 

4-1.

 

Laser/Sensor Offset .................................................................................................4-1

 

4-2.

 

OCC offset................................................................................................................4-8

 

4-3.

 

CAL block offset .....................................................................................................4-17

 

4-4.

 

Head offset .............................................................................................................4-19

 

4-5.

 

VCS offset ..............................................................................................................4-26

 

4-6.

 

Coplanarity offset ...................................................................................................4-42

 

4-7.

 

ATC offset...............................................................................................................4-45

 

4-8.

 

CVS offset ..............................................................................................................4-49

 

4-9.

 

Conveyor offset ......................................................................................................4-51

 

4-10.

 

Pick-up reference position offset ............................................................................4-54

 

4-11.

 

General placement offset .......................................................................................4-56

 

4-12.

 

θ

-axis offset ............................................................................................................4-60

 

4-13.

 

PLCC offset ............................................................................................................4-61

 

4-14.

 

SOT inspect unit offset ...........................................................................................4-62

 

4-15.

 

VAC-CAL offset ......................................................................................................4-64

 

ii 

Rev. 1.00

 

Содержание KE-2070

Страница 1: ...High Speed Flexible Mounter KE 2070 KE 2080 MS PARAMETER JUKI CORPORATION SMT CENTER CUSTOMER SERVICE DEPT ELECTRONIC ASSEMBLY TEST SYSTEMS DIV...

Страница 2: ...as carefully as possible However if you have a question or find a mistake or missing information contact our dealers or JUKI Corp 4 JUKI Corp is not responsible for any defects or malfunction due to y...

Страница 3: ...r make sure that no work personnel exist inside the machine Before turning ON the power make sure that no objects such as adjustment tools hindering any operation inside the machine are mounted or pla...

Страница 4: ...ns 3 1 3 2 Square adjustment 3 2 3 3 Origin rough adjustment 3 5 3 4 XY axis correction coefficient 3 6 3 5 Options 3 7 3 6 Action specifications 3 9 3 7 X axis curve correction 3 14 3 8 Comment 3 15...

Страница 5: ...cuum calibration 4 67 5 Upgrade 5 1 5 1 VCS 5 1 5 2 I O 5 2 5 3 B F 5 3 5 4 LNC60 5 4 5 5 Servo Amp 5 5 6 Delete software 6 1 6 1 I O 6 1 6 2 B F 6 2 6 3 JVS 6 3 7 Others 7 1 7 1 CAL piece holder 7 1...

Страница 6: ...d and the action motion specifications Offset set up that records errors to the design values during assembly and Upgrade that upgrades the operation software after replacement of the control board an...

Страница 7: ...menu e The MS parameter initial screen will appear f To exit the MS parameter click the X mark at the upper right corner of the MS parameter initial screen Or select Exit from the File menu or click...

Страница 8: ...KE 2070 2080 MS Parameter 1 3 Rev 1 00...

Страница 9: ...icted as the head is moved smoothly 1 3 Configuration The MS parameter operation menu is classified into three groups Initial set up Offset set up and Others Initial set up This setup is used when ins...

Страница 10: ...s OPT2070S DAT Information on optional units and optional operations POS2070S DAT Assembly dimensions related to mechanical units of the machine SUP2070S DAT Machine setup information Additionally bac...

Страница 11: ...KE 2070 2080 MS Parameter e Select the save destination and then click Next f Check the contents to be saved and the save destination and then click Next g Select Action 1 6 Rev 1 00...

Страница 12: ...KE 2070 2080 MS Parameter h The progress status is displayed When the backup is completed the following screen will appear Select Finish i The following file has been created 1 7 Rev 1 00...

Страница 13: ...up file follow the steps below c Select Control Data Management from the File F menu d The Control data files storage wizard will appear In this window check on 4 Restore control data from disk and cl...

Страница 14: ...in Restoring origin check that the device set in Restoration end is correct and then click Next g Select Action h The progress status is displayed When the backup file is restored completely the follo...

Страница 15: ...c Select Control Data Management from the File F menu d The Control data files storage wizard will appear In this window check on 1 Backup control data to flash memory and click Next e Check the cont...

Страница 16: ...KE 2070 2080 MS Parameter f Select Action g The progress status is displayed When the backup is completed the following screen will appear Select Finish 1 11 Rev 1 00...

Страница 17: ...w c Select Control Data Management from the File F menu d The Control data files storage wizard will appear In this window check on 3 Restore control data from flash memory and click Next N 1 12 e Sel...

Страница 18: ...KE 2070 2080 MS Parameter f Select Action g The progress status is displayed When the backup is completed the following screen will appear Select Finish 1 13 Rev 1 00...

Страница 19: ...n only data is changed this change is not valid Pay special attention to this point Additionally if you select Cancel the changes you have made become invalid 1 5 2 Limitations The ORIGIN switch is in...

Страница 20: ...it You cannot select a menu corresponding to the units set as not mounted in Options O of Initial set up I 2 2 Menu contents KE2070 2080 Note 1 All heads All heads 1st mark of CAL block is recognized...

Страница 21: ...center of the OCC will move to the selected position If you select Optional pos the following XY moves to a given coordinate dialog box will appear Input coordinates in the Moving target position fiel...

Страница 22: ...on not in use Press the Alt and keys at the same time The following list will appear KE 2070 KE 2080 Input a coordinate in the Moving target position field and select the MOVE button or press the F3...

Страница 23: ...control 2 6 Light map If you select Light map L from the control menu the following Light map control dialog box will appear Select a direction and input a line No and then select the Exec button or p...

Страница 24: ...e lit checked off If you select OK the VCS lights are lit with set contents when selecting the VCS illumination control next time If you select CANCEL the set contents become invalid 2 8 Nozzle up cyl...

Страница 25: ...tion Settings for optional machine types 3 1 2 Required jig This setup requires no jigs 3 1 3 Operation If you select Mech specifications C from the Initial set up I menu the following Conveyor specif...

Страница 26: ...etails about support table offset see Chapter 4 Offset set up described in a later part of this manual If you select Adjust square G from the Initial set up I menu the following Adjust square dialog b...

Страница 27: ...setting processes are completed Select Exec to return to the initial operation screen If the value of Magnet SW adjustment which has been obtained automatically is beyond a range of 0 08mm to 0 08mm a...

Страница 28: ...letion of the operation press the OK button and the left screen will appear Selecting Yes will automatically set up the parameter for the Correction coefficient of XY axis stated in section 3 4 XY axi...

Страница 29: ...results the offset to the design value is displayed If an error occurs during recognition of the mark the offset display is cleared Screen 2 5 Using the teaching function adjust the CAL block position...

Страница 30: ...ed only when JUKI instructs to change the settings 3 4 2 Required jig This setup requires no jigs 3 4 3 Operation If you select Correction coefficient of XY axis X from the Initial set up I menu the f...

Отзывы: