KE-2070/2080 MS
Parameter
3-4. XY axis correction coefficient
3-4-1. Function
The XY axis correction coefficient values obtained in the square adjustment have been input
before shipment.
Therefore, these coefficients need to be changed only when JUKI instructs to change the
settings.
3-4-2. Required
jig
This setup requires no jigs.
3-4-3. Operation
If you select [Correction coefficient of XY axis (X)...] from the [Initial set-up (I)] menu, the
following [Correction coefficient of XY axis] setup dialog box will appear.
CAUTION
Normally, this measurement is performed only at the factory. If the
correction coefficient of an axis is lost accidentally, input
"1.000000".