– 50 –
All contents of functon settng of DDL-8700A-7 can be returned to the standard set values.
) Turn ON the POWER swtch wth all of swtch
4
, swtch
5
and
swtch
6
held
pressed.
2) "rS" s dsplayed on ndcator
B
wth a blp to
start ntalzaton.
3) The buzzer sounds after approxmately one sec-
ond (single sound three times, “peep”, “peep”,
and “peep”), and the setting data returns to the
standard settng value.
(caution) Do not turn oFF the power on the way
of initializing operation. Program of the
main unit may be broken.
4) Turn OFF the power swtch and turn ON the
power swtch after closng the front cover. The
machne returns to the normal moton.
(caution) 1. When you carry out the aforementioned operation, the neutral position correction value for
the pedal sensor is also initialized. It is therefore necessary to carry out automatic correc-
tion of the pedal sensor neutral position before using the sewing machine. (refer
tomatic compensation of neutral point of the pedal sensor” p.43
2. When you carry out the aforementioned operation, the machine-head adjustment values are
also initialized. It is therefore necessary to carry out adjustment of the machine head before
using the sewing machine. (refer
-2. Adjusting the machine head” p.52
3. Even when this operation is performed, the sewing data set by the operation panel cannot
be initialized.
6
5
4
B
17. Initialization of the setting data