– 26 –
Sewing can be performed with the production support data displayed on the control panel.
[Basic operation of the production support modes]
1) When
switch
7
is pressed in the normal
sewing state, LED
E
lights up to enter the pro-
duction support mode.
2) Production support function can be changed
over by pressing
switch
3
or
switch
4
.
3) Data attached marked with (*1) in Table 1 "In-
dicator
A
" can be changed by means of
switch
5
and
switch
6
.
4) When you keep
switch
6
held pressed for two seconds, indicator
B
and LED
E
flash on and
off. While they are flashing on and off, data marked with (*2) in Table 1 "Display under modes" can be
changed by pressing
switch
5
and
switch
6
.
When you press
switch
7
, the value marked with (*2) is confirmed and indicator
B
and LED
E
stop
flashing on and off.
5) The value with a sharp mark (*3) in Table 1 "Display of modes" can be changed only immediately after
resetting by using
switch
5
and
switch
6
.
6) Refer to the table "Mode resetting operation," for the resetting procedure of data.
7) To return to the normal sewing state, press
switch
7
.
Data to be displayed under the respective modes are as described in the table below.
Table 1: Display of modes
Mode name
Indicator
A
Indicator
B
Indicator
B
(when
switch
5
is pressed)
Target No. of pcs. display
mode (F100)
Actual number of pieces (Unit
: piece) (*1)
Target number of pieces (Unit
: piece) (*2)
-
Target/actual No. of pcs. dif-
ference display mode [F200]
Difference between target
number of pieces and actual
number of pieces (d : piece)
(*1)
Target pitch time
(Unit : 100 msec) (*2)
-
Sewing machine availability
rate display mode (F300)
oP-r
Sewing machine availability
rate in the previous sewing
(Unit : %)
Display of average avail-
ability rate of sewing
machine (Unit : %)
Pitch time display mode
(F400)
Pi-T
Pitch time in the previous
sewing (Unit : 1sec)
Display of average pitch
time (Unit : 100 msec)
Average number of revolu-
tions display mode (F500)
ASPd
Average number of revolu-
tions in the previous sewing
(Unit : sti/min)
Display of average number
of revolutions
(Unit : sti/min)
Bobbin counter display
mode
bbn
Bobbin counter value (*3)
-
6
5
4
3
7
A
B
E