– 95 –
Error
code
Display
Description of error
Display message
How to re-
cover
Place of
recovery
E050
Stop switch
When stop switch is pressed
during machine running.
Possible to
re-start af-
ter reset.
S t e p
screen
E052
Thread breakage detec-
tion error
When thread breakage is
detected.
Possible to
re-start af-
ter reset.
S t e p
screen
E061
Memory switch data error
Memory switch data is bro-
ken or revision is old.
Turn OFF
the power
E080
External stop switch
Possible to
re-start af-
ter reset.
S t e p
screen
E204
USB connection error
With the number of times of
sewing has reached 10 or
more, with a USB device con-
nected to the sewing machine
Possible to
re-start af-
ter reset.
S e w i n g
screen
E220
Grease-up warning
At the time of operation of
100 million stitches
→
R e f e r t o
.
Possible to
re-start af-
ter reset.
Data
input
screen
E221
Grease-up error
At the time of operation of
120 million stitches
The sewing machine is
put in the sewing-impossi-
ble status. It is possible to
clear with memoryswitch
.
→
R e f e r t o
.
Possible to
re-start af-
ter reset.
Data
input
screen
E305
Cloth cutting knife posi-
tion error
Cloth cutting knife is in the
regular position.
Turn OFF
the power
Data
input
screen
E306
Thread clamp position er-
ror
Thread clamp unit is not in
the regular position.
Turn OFF
the power
E307
External input command
time out error
Input is not performed for a
fixed period of time with the
external input command of
vector data.
Possible to
re-start af-
ter reset.
Data
input
screen