– 4 –
Within 0.3 mm
1. Fix the throat plate auxiliary
cover
3
so that is higher
than the throat plate
2
(within
0.3 mm). When it is lower
than the throat plate
2
, nee-
dle breakage or the like due
to the defective feed will be
caused.
2. Confirm by putting a ruler or
the like that the throat plate
auxiliary cover
3
is horizon-
tally installed. If not, throat
plate auxiliary cover
3
and
lower plate
1
come in con-
tact partially with each other,
and abnormal worn-out will
be caused.
3
3
2
3
1
L
1
2
r
a
B
c
D
3-2. table position adjustment: only for 6030
For the 6030, the table has been retracted from the normal poston n the factory n pror to shpment.
After unpackng, be sure to carry out the followng steps 1) through 9).
Poston adjustment for the
left table
L
s descrbed as an
example. Adjust the poston of
the rght table
r
n the smlar
manner.
[accessories to be used]
a
: Table fixing bolt cover
HX00326000B x 2
B
: Power swtch setscrew
SK3512001SE x 2
(Four setscrews are used for the table of the
machne for JE.)
c
: Operaton panel stopper
40072231 x 2
D
: Operaton panel stopper setscrew
SK3271301SE x 2
1) Remove screws
1
and
2
to remove the cover.
* When removng screw
2
, take care not to lose
the nut secured on the undersde of the table.