JUDO QUICKSOFT MEGA
Operation
5.7
Potential-free fault indication
A general error message can be forwarded
by the potential-free relay in the following
cases:
– In the event of a water softening system
fault indication
– If there is a power loss
– If a low salt condition exists
Chapter 2.1 „Indication of particular dan-
gers“ must be observed without fail!
Adhere to the maximum switching current
and maximum voltage (see chapter 2.1.1
“Electrical devices/installations”)!
The contacts of the potential-free relay are
shown in the zero-current state in fig. 7.
Setting the switching function:
Press key
1x and then key
2x. The
display indicates the following:
Press key <OK> 1x and then key
as often
as necessary, until the display indicates the
following:
Press the <OK> key. The display indicates
the following:
Press key
or
to change between <Nor-
mally open> and <Normally closed>.
The chosen setting is saved by pressing
<OK>.
5.8
Integration of the water
softening system
in building control systems
The water softening system can be integrat-
ed via the potential-free relay into a building
control system (e.g. EIB, LCN or LON).
For example, the potential-free relay is con-
nected to a binary bus coupler. This allows a
fault indication to be forwarded to the build-
ing control system.
5.9
Connectivity module
(accessories)
A retrofittable connectivity module is used to
connect the water softening system via a
LAN connection to the home network and
the Internet.
Using the available iOS/Android app, world-
wide access to comprehensive information,
automated messages and functions of the
water softening system is possible.
Prior to electrical installation, pull the
power supply unit out of the socket!
Main menu
• Settings
Setting
• Fault relay
Fault relay
Normally open
The fault signalling cable is not
part of the scope of supply.
Содержание QUICKSOFT MEGA
Страница 3: ...JUDO QUICKSOFT MEGA 3...
Страница 13: ...JUDO QUICKSOFT MEGA 13 Operation 5 4 Menu structure Fig 6 Menu structure...
Страница 22: ...22 JUDO QUICKSOFT MEGA Data sheet Fig 7 Electronic control unit with fault message relay...
Страница 25: ...JUDO QUICKSOFT MEGA 25 Notes...
Страница 26: ...26 JUDO QUICKSOFT MEGA Notes...
Страница 27: ...JUDO QUICKSOFT MEGA 27 Notes...