Judo QUICKSOFT MEGA Скачать руководство пользователя страница 7

JUDO QUICKSOFT MEGA

7

Intended use

The water softening system must only be
used as intended in a technically fault-free
state, while maintaining safety and hazard
awareness, and in compliance with the oper-
ating instructions.

Ensure that malfunctions are rectified
immediately!

The spent regenerating salt is removed from
the water softening columns together with
waste water. Therefore it must not be used
for irrigation or similar purposes.
The designed capacity of the water softening
system is such that it is capable of partially
softening the entire water requirement for a
single or multiple family house as well as cor-
responding partial water quantities for hot
water, swimming pool, washing machine and
dishwasher.

2.1

Indication of particular dan-
gers

2.1.1 Electrical devices/installations

Electrical devices/installations that are not
splash-proof and are located in the vicinity of
the water softening system may be dam-
aged by water that escapes during regener-
ation or in the event of incorrect use of the
water softening system. If the electrical de-
vices/installations are connected to the pow-
er supply, it is also possible that a short-cir-
cuit could occur. Should this occur there is a
risk of electric shocks to people. Therefore
electrical devices/furnishings and equip-
ment in the vicinity must be splashproof and/
or comply with the legal regulations for wet
areas.

Caution when touching without the cover!
During operation, electronic components
can become hot. Also there is a danger due
to moving parts.

Potential-free output

Switching voltage............. maximum 24 V

Current ................................ maximum 1 A

(see chapter 5.7 “Potential-free fault indica-
tion”)

No electrical cables and equipment
may be located below or in the im-
mediate vicinity of the water soften-
ing system!

In the power supply unit the mains
voltage is reduced to a safe low volt-
age of 24 V which is then used to op-
erate the system electronics. No oth-
er power supply units must be used.

Only low voltages can be used for
the remote transmission of the fault
indication via the potential-free out-
put!

Содержание QUICKSOFT MEGA

Страница 1: ...Read before use and store Operating instructions JUDO QUICKSOFT MEGA Water softening unit Valid for EU countries and Switzerland Language English...

Страница 2: ...he confidence you have shown in us by purchasing this device In purchasing this water softening system you have procured a state of the art device This device is suitable for use in cold drinking wate...

Страница 3: ...JUDO QUICKSOFT MEGA 3...

Страница 4: ...ee fault indication 16 5 8 Integration of the water softening system in building control systems 16 5 9 Connectivity module accessories 16 5 10 Conversions changes spare parts 17 5 11 Service repair 1...

Страница 5: ...able to fulfil the instructions referred to in the installation and operating instruc tions as well as country specific regulations Alongside the operating instructions and the legal regulations appli...

Страница 6: ...The water to be softened must comply with the European Drinking Water Direc tive The manufacturer supplier must be consult ed before using water of a different quality or water with additional additiv...

Страница 7: ...m aged by water that escapes during regener ation or in the event of incorrect use of the water softening system If the electrical de vices installations are connected to the pow er supply it is also...

Страница 8: ...mical and corrosive loads expected to be encountered in drinking water and fulfil the specifications required by DIN EN 14743 and DIN 19636 100 Water soften ing systems cation exchangers in drinking w...

Страница 9: ...ter hardness Raw water hardness setting see chapter 5 3 3 Setting the raw water hardness Regeneration manual regeneration start see chapter 5 3 2 Manually starting regen eration of the water softening...

Страница 10: ...re used then the salt reservoir must be cleaned at shorter intervals and the intake strainer replaced more frequently Remove the cover Enter the date of installation on the label see fig 3 Open the wa...

Страница 11: ...h a reduced water volume is treated If the raw water hardness is low a greater wa ter volume is treated The water softening system is pre set to a raw water hardness of 25 e Another raw water hardness...

Страница 12: ...r limit values are much higher partially greater than 1000 mg sodium per litre If the calculated total sodium content ex ceeds the valve permitted by the drinking water legislation of 200 mg l then it...

Страница 13: ...JUDO QUICKSOFT MEGA 13 Operation 5 4 Menu structure Fig 6 Menu structure...

Страница 14: ...available for the consumer even during regeneration 5 5 3 Regeneration With a very short regeneration period of about 7 5 minutes per resin container total 15 minutes high volume continuous draw ing i...

Страница 15: ...rine concentration de creases too much a message is output to the display After this message replenishment with a quantity of 25 kg of regenerating salt is re quired Then the OK key must be briefly pr...

Страница 16: ...key or to change between Nor mally open and Normally closed The chosen setting is saved by pressing OK 5 8 Integration of the water softening system in building control systems The water softening sy...

Страница 17: ...or the bypass valve is switched over When disassembled the water softening system must be stored in a dry and frost free location The connection flange must be protect ed against dirt and damage Once...

Страница 18: ...tion Maintenance Service req Message appears after the one year service interval has elapsed see chapter 8 3 1 Message Mainte nance Service Attention Salt deficit Message appears after exceeding of th...

Страница 19: ...hygiene measures Thus for example the salt packs should be cleaned before use so that no impurities can get into the salt dissolving container The re generating salt must be shaken into the salt diss...

Страница 20: ...s lower to ensure the optimum function of the water softening system Further information can be found in the in stallation instructions 1703525 for the QUICKSOFT MEGA 6 water softening unit Operating...

Страница 21: ...dation Installation of a JUDO JULIA dosing pump in the mixing water pipe downstream of the water softening system so that the water can be admixed proportionally with a JUL mineral solution The JUL mi...

Страница 22: ...22 JUDO QUICKSOFT MEGA Data sheet Fig 7 Electronic control unit with fault message relay...

Страница 23: ...JUDO QUICKSOFT MEGA 23 Spare parts 10 Spare parts Fig 8 Spare parts JUDO QUICKSOFT MEGA 1 A 2 4 3 B 5 6 7 8 8 9 9 10 11...

Страница 24: ...or 2200582 88 Spare part set injector 2201470 78 A Spare part set hoses complete 2200012 25 B Spare part set overflow connection 2202230 38 1 Power supply unit EU 24 V DC 2210506 65 2 Lance 2201855 13...

Страница 25: ...JUDO QUICKSOFT MEGA 25 Notes...

Страница 26: ...26 JUDO QUICKSOFT MEGA Notes...

Страница 27: ...JUDO QUICKSOFT MEGA 27 Notes...

Страница 28: ...bH Filiaal Filiale BeNeLux Laarbeeklaan Av du Laerbeek 72 A1 B 1090 Brussel Bruxelles Tel T l 32 0 24 60 12 88 Fax 32 0 24 61 18 85 e mail info benelux judo eu judo eu JUDO France S r L 76 Rue de la P...

Отзывы: