12
JUDO QUICKSOFT-DUO
Operation
5.
Operation
ATTENTION
(see chapter “Safety information and
dangers due to non-compliance”)
Always observe the chapter on “Intended
Use”!
5.1
Commissioning
activate regeneration:
–
Fill the regeneration salt into the salt
container (5). The water dissolves the
regeneration salt producing saturated
brine . The regeneration salt must at
least conform to food quality standards
and should fulfil the requirements
according to DIN EN 973.
–
Our recommendation: Broxo or Solvay
salt, either as a block, tablets or coarse
grains 7 - 15 mm (0.3 - 0.6 inches). If you
use other regenerating salts, the salt
container (5) must be cleaned at shorter
intervals and the intake screen (88)
replaced more often.
–
Pour approx. 4 litres of water into the salt
container (5).
–
Remove the cover (2).
–
Enter the installation date on the label of
the operating cylinder (36) and in the
“servicing record sheet”.
–
Set the raw water hardness (
°
e) at the
electrical circuit (see chapter “Setting the
raw water hardness”).
–
Open the water inlet. Open the bypass
valve.
ATTENTION
For safety reasons the softener must be
vented immediately after it is connected to
the water system (bypass valve is open).
The system is automatically vented during
the first regeneration (see chapter
“Commissioning”).
–
After each connection to the power
supply the electronics automatically
perform a self-test for approx. 10
seconds. After this has been success-
fully completed all the control lamps
briefly light up The system control lamp
(13) then lights up.
–
Trigger regeneration manually: Press
the regeneration trigger (18). At the
same time you can check whether the
system is functioning correctly (see
chapter “Servicing / Repair”).
After completing the regeneration the
softener is ready for use (approx.15
minutes).
The intake time should be at least 30
seconds (digit 2 can be seen on the
driving wheel (11)). If the intake time is
shorter, water must be poured into the
salt container (5). Filled level 4 - 4.5
inches above the floor of the container.
Start a new regeneration and check the
intake time.
–
Mix in hard water using the setting screw
of the blending valve (10) (see chapter
“Setting the blending”).
–
Fit the cover (2).
Connect the softener to the
power supply. Plug the power
pack into the socket.