8
JUDO SPEEDY-LongLife
Installation
4.1.1 Requirements for the place of
installation
The room where the unit is installed must
be dry and frost-free!
Unauthorised persons must not have
access to the filter!
ATTENTION
(see chapter “Safety information and
dangers due to non-compliance”)
–
The ambient temperature must not
exceed 86 °F (30 °C)! At higher tempera-
tures or direct sun radiation the material
can be damaged and the filter hood can
even break.
–
In order to be able to safely discharge
the wastewater in operation and in case
of any defects that occur in the system,
precise compliance with the details
given in the “Installation” chapter is
necessary! If the wastewater (back-
washing) cannot be safely and
completely discharged, then this may
result in water damage to the house and
installations therein.
–
A shut-off valve must be installed
upstream of the filter! This enables the
water supply to the filter to be interrupted
during installation, servicing/main-
tenance, repairs and in case of malfunc-
tions. Floods and serious water damage
to house installations can therefore be
avoided.
–
The unit can be installed in all standard
drinking water pipes.
–
It is not permitted to install the backwash
protective filter
upstream of
the
water
meter!
4.1.2 Installed position
ATTENTION
(see chapter “Safety information and
dangers due to non-compliance”)
Always install the filter in a vertical position
(± 5°)!
Failure to observe this can cause uncon-
trolled backwashing water to escape and
can result in water damage.
4.1.3 Mounting the built-in rotary
flange
Install using the supplied built-in rotary
flange. The built-in rotary flange is used as a
connecting element between the pipe and
the filter.
The built-in rotary flange must be
installed in an arrow on the flange.
Failure to comply with this means that back-
washing is impossible. By and by this leads
to an increasing pressure loss.
ATTENTION
(see chapter “Safety information and
dangers due to non-compliance”)
The flange surface of the built-in rotary
flange must be in a horizontal position! The
built-in rotary flange must be fitted so that
mechanical stresses cannot occur! Other-
wise mechanical damage can result in the
built-in rotary flange. Otherwise mechanical
damage can result, the pipe may burst or the
built-in rotary flange can break. This can
result in major water damage.
In this case, people close to the filter are
exposed to a health risk due to the large
quantities of water.
Therefore, during installation, ensure that no
large forces act on the pipe, built-in rotary
flange and filter.