Judo JSY-LF Скачать руководство пользователя страница 2

2

JUDO SPEEDY-LongLife

Corporate head office

JUDO Wasseraufbereitung GmbH

P.O. Box 380

D-71351 Winnenden

Germany

e-mail: [email protected]

judo.eu

Manufacturing plant

JUDO Wasseraufbereitung GmbH

Hohreuschstraße 39-41

D-71364 Winnenden

Germany

Trademarks:
Trademarks used in this document are protected 
and registered trademarks of the respective 
holder.

© JUDO Wasseraufbereitung GmbH
D-71364 Winnenden

All rights reserved.
Reprints – even of extracts – are only permitted 
with special written approval.

Dear customer,
we would like to thank you for your confi-
dence in us, which you have shown by
purchasing this device. The product you
have purchased is a filter developed
using state of the art technology.

This filter is suitable for use in cold
drinking water up to a maximum ambient
temperature of 86 °F (30 °C).

It removes coarse and fine-grained parti-
cles larger or equal in size to the filter
screen (strainer) mesh from the filter
through screen filtration.

Particles smaller than the screen mesh
size used, change turbidities (i.e.
substances that make the water turbid)
and substances dissolved in the water
cannot be filtered out of the water.

Each unit is thoroughly checked before
delivery. However should difficulties
occur, please contact your regional
customer service (see back page).

Содержание JSY-LF

Страница 1: ...s and safety information before installing and putting the unit into service These instructions must always be issued to the owner user Installation and operating instructions JUDO SPEEDY LongLife Bac...

Страница 2: ...your confi dence in us which you have shown by purchasing this device The product you have purchased is a filter developed using state of the art technology This filter is suitable for use in cold dri...

Страница 3: ...permanently be available at the place where the filter is in installed This instruction manual is intended to make it easier to familiarize yourself with the filter and its possible intended uses The...

Страница 4: ...ve the general danger symbols can result for example in the following risks failure of important functions of the backwash protective filter danger to persons due to electrical and mechanical effects...

Страница 5: ...y regulations generally accepted in Germany The filter may only be operated in accor dance with the manufacturer s specifica tions Any other operation or operation beyond the specified use is not in a...

Страница 6: ...plash water proof and are situated in the direct vicinity of the backwash protective filter may be damaged by water leaking from the backwash protective filter caused as a result of the device not bei...

Страница 7: ...uidelines of the German federal environmental agency and the DVGW work sheet W270 Metallic materials fulfill the requirements of the German stan dard DIN 50930 6 Impact on the drinking water quality 4...

Страница 8: ...o install the backwash protective filter upstream of the water meter 4 1 2 Installed position ATTENTION see chapter Safety information and dangers due to non compliance Always install the filter in a...

Страница 9: ...tween the sleeves insert the flat seals and screw using the union nut The cast in arrow of the built in rotary flange must match the direction of flow of the water ATTENTION see chapter Safety informa...

Страница 10: ...h the filter the flushing water can be fed several meters to the next wastewater connection either through a hose or a pipe to be fitted to the flushing water valve This pipe must have the same dimens...

Страница 11: ...4 2 1 Backwashing water discharge options JSY LF 1 JSY LF 1 2 Fig 4 Backwashing water discharge options min 10 l 200 mm 8 inch 200 mm 8 inch min 10 l 200 mm 8 inch 200 mm 8 inch 20 mm 0 8 inch 40 mm 1...

Страница 12: ...the installation caused by pressure surges The filter is vented by means of backwashing see chapter Discharging the backwashing water After backwashing and venting the filter is ready for use 5 2 Func...

Страница 13: ...JUDO SPEEDY LongLife 13 Operation Fig 5 Functional description built in rotary flange indicator button for the next backwashing filter hood handwheel for free discharge...

Страница 14: ...ing process can be repeated if necessary ATTENTION see chapter Safety information and dangers due to non compliance This backwashing process must be carried out until the audible locking into place of...

Страница 15: ...can deform the screen and as an extreme incident cause the tearing of the sieve As a result a filter function is not any longer ensured In addition larger quan tities of dirt can cause mechanical imp...

Страница 16: ...me loose at operating pressure or that it can burst Leaking water can cause major material damages to the building In addition people near the filter can be injured by blistering filter parts When re...

Страница 17: ...r alcohol spirits and may not be used These substances can chemically attack the plastic parts which can lead to brittleness right up to brittle fractures These kinds of cleaners must therefore not be...

Страница 18: ...Germany The maximum operating pressure is lower in order to ensure the optimum function of the filter The backwashing volumetric flow given applies to 29 44 psi 200 300 kPa mains pressure and for a co...

Страница 19: ...ade of the manual backwash protective filter to an auto matic backwash protective filter Fig 6 Installation dimensions JSY LF 1 Fig 7 Installation dimensions JSY LF 1 2 JSY LF JSY LF 1 JSY LF 1 JSY LF...

Страница 20: ...20 JUDO SPEEDY LongLife Spare parts 10 Spare parts 10 1 JSY LF 1...

Страница 21: ...rew M 6 x 30 4 1650209 5 Profile flange seal 1 1200218 6 Strainer 1 2070302 7 Suction Pipe 1 1120674 8 O ring 18 x 2 5 2 1200291 9 Pre fitted flushing valve 1 2170179 10 Suction pipe base 1 1120533 11...

Страница 22: ...22 JUDO SPEEDY LongLife Spare parts 10 2 JSY LF 1 2...

Страница 23: ...ng 18 x 2 5 2 1200291 7 Pre fitted flushing valve 1 2170179 8 Suction pipe base 1 1120464 9 Filter hood 1 2170575 10 Flange 1 1430099 11 Display button 1 1120424 12 Cover filter hood JSY LF 1 1 217024...

Страница 24: ...served for modifications as a result of technical progress or further developments Claims with regard to models or products are excluded 1701609 2014 06 JUDO Water Treatment Inc 240 Lesmill Road Toron...

Отзывы: