Safety

An adequately sized waste water con-

nection (e.g. floor drain) in compliance

with DIN 1986 must be provided.
In order to ensure safe drinking water

hygiene, a free discharge of the waste

water acc. to DIN EN 1717 must be

ensured.
The pipe must be able to safely sup-

port the device (weight: see chapter 7).

If necessary, the pipes must be provided

with additional fastenings or support.
If no bypass valve is installed, a shut-

off valve must be installed upstream of

the unit in order to interrupt the water

supply during installation, maintenance,

repair or malfunction of the device.

Only operate the device in a technically

faultless condition:

Check for damage prior to installa-

tion.

Immediately have any malfunctions in

operation rectified by qualified tech-

nical personnel.

Persons who, due to their physical, sen-

sory or mental abilities or their inexperi-

ence or lack of knowledge, are unable to

operate the device safely may not oper-

ate it without supervision or instruction

from a responsible person.
Regular backwashing of the device is

required to ensure safe drinking water

hygiene (see chapter 4.1.1).
Before carrying out a backwash, ensure

that the wastewater connection is func-

tional.
At the end of the backwashing process,

turn the handwheel until it engages so

that no more backwash water escapes.

Otherwise, water may constantly escape

and cause water damage.
Do not use household cleaning agents

to clean the outside of the device, but

only use clear water to avoid embrittle-

ment of the plastic.

The device may only be repaired by

qualified technical personnel.
Only use original spare parts for repairs.
Before performing work on the device

that goes beyond pure operational use,

the device must be depressurised! If

this is ignored, the result may be uncon-

trolled escape of water resulting in water

damage to the building/home.
If the device is removed due to an inter-

ruption of operation:

Protect the flange surfaces against

damage to ensure proper sealing.

Protect the device from dirt so as not

to impair drinking water hygiene.

Store the device in a frost-free place

to prevent damage caused by freez-

ing water and leakage.

Unauthorised conversions and changes

are forbidden for safety reasons. These

can impair the functioning of the device,

leading to leaks and, in the worse case

scenario, to bursting of the device.

1.4

Symbols used

The safety instructions contained in these

operating instructions are labelled with the

following symbols:

Indication of existing dangers

Warning of electric voltage

User tips and other information

Instructions attached directly to the device,

e.g.:

Direction of flow (arrow)

Type label

Cleaning information

1701803 • 2019/11

JUDO JPF-QC  

5

Содержание JPF-QC DN 125

Страница 1: ...filter DN 125 200 Valid for EU countries and Switzerland Language English Read before use and store Installation and operating instructions JUDO PROFI QC Backwash protective filter DN 125 200 Valid fo...

Страница 2: ...inting even in excerpt form is only permitted with special approval Dear customers Thank you for the confidence you have shown in us by purchasing this prod uct You have purchased a state of the art d...

Страница 3: ...Installation of the device 8 3 3 Draining of the backwash water 9 3 4 Commissioning 10 4 Operation 11 4 1 Cleaning of the sieve insert back washing 11 4 2 Conversions changes 11 4 3 Maintenance repai...

Страница 4: ...e it is essential to consult the manufacturer 1 2 2 Water pressure CAUTION The water pressure must not exceed 10 bar input pressure The device must not be installed if the mains pressure is above 10 b...

Страница 5: ...handwheel until it engages so that no more backwash water escapes Otherwise water may constantly escape and cause water damage Do not use household cleaning agents to clean the outside of the device b...

Страница 6: ...device through the connection flange A coarse fil ter prevents large dirt particles from reach ing the fine filter Coarse dirt collects in the sludge trap The water flows from the out side to the ins...

Страница 7: ...for backwashing 2 Setting ring for the next backwash date 3 Filter hood 4 Flange 5 Waste water connection ball valve with black handle to be closed only in case of a failure 6 Discharge of sludge tra...

Страница 8: ...of the water meter is forbidden 3 1 Conditions CAUTION Risk of property damage or water damage The pipe must be able to safely support the device weight see chapter 7 If necessary the pipes must be p...

Страница 9: ...ackwash water with a pipe make sure that the ball valves are not twisted and that there may be a leak The ball valves are secured with a seal ing adhesive The drain must be large enough so that all of...

Страница 10: ...ter and vent 1 Open the upstream shut off valve to fill the device with water The device is now under mains pressure 2 Attention Carry out a backwashing immediately so that the trapped air can escape...

Страница 11: ...s can impair the backwashing function mechani cally According to DIN EN 13443 1 backwashing the device is required at the latest every six months The manufacturer requires a backwash ing at least ever...

Страница 12: ...trolled egress of water result ing in water damage to the build ing home 4 4 Temporary removal of the device WARNING If the device is removed due to an interruption of operation Protect the flange su...

Страница 13: ...d Perform backwashing There are leaks in the filter bowl Damaged seals Inform the installer or the closest customer service point Filter bowl becomes clouded Hairline cracks on the filter bowl Filter...

Страница 14: ...th the information in chapter 4 1 1 Backwashing interval To ensure the process operates success fully as long as possible regular inspec tion and routine servicing of the device are essential Where ho...

Страница 15: ...ckwashing with 0 2 0 5 bar Druckverlust 100 m h 150 m h 200 m h Mesh size2 sieve insert 100 m 0 1 mm 100 m 0 1 mm 100 m 0 1 mm Water temperature and ambient temperature max 30 C max 30 C max 30 C Thre...

Страница 16: ...s JPF QC DN 200 JPF QC DN 125 JPF QC DN 150 JPF QC DN 200 A 560 560 600 B 250 474 474 C 446 469 485 D 197 215 246 G A Installation length B Unit depth C Height above the pipe middle D Height below the...

Страница 17: ...Technical data 7 2 Spare parts JPF QC DN 125 200 1701803 2019 11 JUDO JPF QC 17...

Страница 18: ...3 Disc A 6 4 1 4 Handwheel 1 5 Spacer 1 6 Adjusting ring 1 7 Sheet metal screw 3 9 22 2 8 Cover filter bowl 1 9 Cylinder screw M8 45 16 10 Flange ring 1 11 Filter bowl 1 2021139 590 12 O ring 15 3 2...

Страница 19: ...bottom JPF QC DN 200 1 29 Nipple 1 30 Ball valve blue handle 1 2021337 52 31 Ball valve black handle 2 4 2021336 52 32 Orifice disc 2 4 2021346 15 List of spare parts JPF QC DN 125 200 1 AU Accounting...

Страница 20: ...online ch judo online ch BENELUX JUDO Wasseraufbereitung GmbH Filiaal Filiale BeNeLux Laarbeeklaan Av du Laerbeek 72 A1 B 1090 Brussel Bruxelles Phone 32 0 24 60 12 88 Fax 32 0 24 61 18 85 E mail info...

Отзывы: