22
JUDO i-soft
Operation
5.8
Resetting to factory settings
The settings for residual hardness and
residual hardness correction can be reset to
factory settings.
In order to do this, press the <OK> key
together with key <10>.
–
Residual hardness 8 °e
–
Correction value = 0
5.9
Display message overview
Display
Description
Further information
Maintenance /
service
Message shown after 1 year of opera-
tion.
(see chapter 8.1
“Message “Mainte-
nance / service””)
Verify salt level
Message comes up after 100 regenera-
tions.
(see chapter 5.3.1
“Message “Verify salt
level””)
Salt reg. counter
reseted
Shown after manual reset of salt quantity
regeneration counter.
(see chapter 5.3.1
“Message “Verify salt
level””)
Attention!
Salt deficit
Shown after value falls below minimum
chlorinating flow.
(see chapter 5.3.2
“Message in case of
insufficient salt”)
Input not possible
Setting a set-point residual hardness
outside the admissible range. The setting
is not transferred.
(see chapter 5.1.2
“Limitations for residual
hardness settings”)
Attention!
Sodium limit value
Due to raw water hardness and the
residual hardness setting, the sodium
threshold value stipulated by the drinking
water regulation is exceeded.
(see chapter 5.1.2
“Limitations for residual
hardness settings”)