Faults
6
Faults
Fault
Cause
Remedy
PE tube is kinked.
Lay PE tube without kinks
T-valve inlet is closed
Open T-valve inlet
Water supply is disconnected
Wait until the water supply is con-
nected
PP + C filter cartridge clogged
PP + C filter cartridge replacement
Water pressure too low
Water pressure increase
Water flow low or not existing
Inlet water temperature is lower
than necessary
Water temperature increase
No power supply
Check power supply
Mains connection adapter defective Mains connection adapter replace-
ment
Device not working
Water supply low
Check water supply. If the water sup-
ply is OK, plug in the mains plug
Device has not been used for a long
time
Flush the filter cartridges for five min-
utes. If there is no improvement,
replace filter cartridges
Poor feed water quality
Feed water quality check
Water tastes bad
Filter cartridges have not been
replaced for a long time
Filter cartridge replacement
Power and voltage do not match
Request JUDO customer service
Water inflow too low
Water inflow increase
Mains connection adapter defective Request JUDO customer service
Device is noisy during operation
Booster pump defective
Request JUDO customer service
Table 10: Faults
If a fault cannot be rectified based on the information in the related table, contact your JUDO customer service
representative or an authorised specialist company.
JUDO customer service addresses can be found on the last page of this manual.