Connection
7. Filter cartridge rinsing
ATTENTION
Before flushing insert all filter cartridges in the device (see chapter
Filter cartridge installation
)
NOTE
Before flushing, check the electrical connection!
Rinse filter cartridges before first use!
PP + activated carbon filter rinsing
Open the lever for purified water at the water tap.
To flush the cartridge, leave the water to run for 10 - 20 minutes until clear water flows out of the water tap.
Close the lever for purified water.
T33/activated carbon filter rinsing
Open the lever for drinking water at the water tap.
To flush the cartridge, leave the water to run for 10 - 20 minutes until clear water flows out of the water tap.
Close the lever for drinking water.
4.4.1
Initial commissioning
Upon first use, open the water tap and the inlet valve. If water now runs, re-close the water tap for 30 minutes.
During this time, check the system for leaks. If there are no leaks, the reverse osmosis system can be used nor-
mally.
During normal use, the device remains connected to mains power and water can be requested by opening and
closing the water tap.
However, if the device has not been used for a longer period, the filter cartridges must be flushed as described in
the chapter
Water connection, step 7
, before its renewed use.
4.5
Electrical connection
Fig. 5: Circuit diagram
1
Power supply unit
5
TDS* measuring sensor inlet
2
Solenoid valve, water inlet
6
High pressure valve
3
Flush valve
7
Control section
4
Booster pump
* TDS = Total Dissolved Solids
07/2021 • 1703434