JUDO i-soft@home
13
Installation
4.5
Installation of the water sof-
tening unit
The connection flange of the water softening
unit is covered by a white protective cap.
This protective cap is secured using four
hexagon socket head screws M6×130.
– Loosen all four hexagon socket head
screws M6×130, but do not screw out
completely (bayonet connection)!
– Remove the white protective cap.
The profile of the profile flange seal must
point towards the bypass valve (see fig. 7).
If this is not observed, water leaks may oc-
cur. This can result in water damage to the
building, furnishings and equipment.
– Raise the water softening unit and swivel
approximately 30° in an anti-clockwise
direction.
– Position the water softening unit on the
“G”-labelled flange (G=Gerät [device]) of
the bypass valve so that the screw
heads project through the bayonet holes
(see fig. 8 I).
– Swivel the water softening unit back ap-
proximately 30° in a clockwise direction.
– Fully tighten the four M6×130 hexagon
socket head screws (see fig. 8 II).
After installation of the water softening unit,
screw out the wall support until it touches
the cladding of the water softening unit and
the device hangs vertically on the wall.
Fig. 7:
Profile flange seal
Select the tightening torque (about
4 Nm) so that the seal is effective
and the water softening unit is not
damaged or strained!
Fig. 8:
Bayonet function (fig. similar)
I
II