JST MP-CB (CE) Скачать руководство пользователя страница 1

 
 

 

MP-CB (CE) 

 

Operation manual 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание MP-CB (CE)

Страница 1: ...MP CB CE Operation manual ...

Страница 2: ...ntrol box connection to MP termination press 4 4 Control box connection to MP cover press 6 5 Control box connection to YA tool 8 6 Air pressure adjustment 9 7 Timer control adjustment 10 8 Counter 11 9 Trouble shooting 12 10 Pneumatic circuit diagrams 13 11 Parts list 15 ...

Страница 3: ...E please read this manual to ensure that you are familiar with its operating controls We recommend that you keep this manual near the control box for future reference This equipment complies with relevant CE Directives for incorporation with other machinery WARNING This unit must only be used with a suitable dry pneumatic supply Do not operate this unit with any pneumatic tubing disconnected CAUTI...

Страница 4: ...Page 3 of 15 MP CB CE 2 Specifications Model MP CB CE Dimensions mm 200 H x 130 W x 320 D Weight 4kg Air supply 75 100 Psi ...

Страница 5: ...ort marked No 1 on the footswitch Connect pipe No 2 from the control box to the main air to the footswitch connection 2 Carriage sensor Connect pipe No 3 from the control box to the lower connection on the carriage sensor Connect pipe No 4 from the control box to the upper connection on the carriage sensor Main supply Port marked No 1 ...

Страница 6: ...ss 3 MP press connection Connect pipe No 1 from the control box to the No 1 connection on the MP press cylinder Connect pipe No 2 from the control box to the lower connection on the press 4 Connect the main air supply to the control box and check the air pressure is 75 100 Psi ...

Страница 7: ...rt marked No 1 on the footswitch Connect pipe No 2 from the control box to the main air to the footswitch connection 2 Carriage sensor connection There is not a carriage sensor on the cover fitment presses Connect the small length of 4mm pipe into No 3 and No 4 carriage sensor connections on the control box Main supply Port marked No 1 ...

Страница 8: ...s cylinder Connect pipe No 2 from the control box to the lower connection on the press 4 Connect the main air supply to the control box and check the air pressure is 75 100 Psi Note When the press is in standby waiting for termination there should be no air leaks If anything appears to be working abnormally check all connections are correct or see the trouble shooting section ...

Страница 9: ...nnect the main port right angle connector on the foot pedal to number 2 footswitch on the control box 4 The carriage sensor should have a loop fitted between 3 and 4 as shown 5 Connect the red port on the YA tool to press 1 on the control box 6 Connect the black port on the YA tool to press 2 on the YA tool 7 Connect the main air supply to the control box Stem plug 8mm Stem reducer 4mm 8mm Reducer...

Страница 10: ...ssure adjustment 1 Move the air pressure control knob upwards this will allow any adjustment that is required Turn the knob to achieve the recommended air pressure push it back downwards to lock the adjustment Air pressure 75 100 Psi ...

Страница 11: ... cover upwards and off 2 On top of the control box is a small hole in this hole is the screw to adjust the timer delay 3 Turn the screw to adjust the timer delay Turning the screw clockwise will increase the timer delay 4 Refit the vent cover after adjustment is complete ...

Страница 12: ...Page 11 of 15 MP CB CE 8 Counter To reset the counter to zero press the blue button ...

Страница 13: ...te is pushed forward to the carriage sensor Check that the foot switch is connected correctly The press ram is continually in the termination down position Check that the main cylinder pipes are connected correctly both at the press and at the control box An air leak from the foot switch stops leaking when the foot switch is operated Check the foot switch connections are correct at the control box...

Страница 14: ...Page 13 of 15 MP CB CE 10 Pneumatic circuit diagrams MP CB CE used with MP termination press ...

Страница 15: ...Page 14 of 15 MP CB CE 8 Pneumatic circuit diagrams MP CB CE used with a MP cover fitment press or a YA tool ...

Страница 16: ...ase 14 Single sub base din rail mount 81 532 104 1 Inside case 15 1 8 silencer AN103 01 3 Main valve and dump valve 16 Bulkhead union 6mm tube KQE06 00 2 Press connections rear panel 17 Pilot spring valve 5 2 SYA5120 01 1 Main valve inside case 18 Plug in or gate 81 540 001 1 On rear panel connections inside case 19 Push button mushroom VM 30AR 1 Top panel 20 3 2 plunger actuated valve VM430 01 00...

Отзывы: