JSB RS64 Скачать руководство пользователя страница 4

2

Function Keys and Status Lights
These keys are used to select
different operating modes and to
reset after an alarm. These Status
lights indicate System Status.
(See pages 3 to 5)

Numeric Keys and Zone Lights
These keys are used for entering
your security code to turn the
system on and off. These keys are
also used to program the
system. Eack key incorporates a
Zone/Status light.
(See pages 7 to 11)

DESCRIPTION OF SOUNDS

Keypad press

- Quick blip

Entry sound

- Solid tone pulsed on and 

off slowly

Exit sound

- Solid tone

Tamper sound - Fast Broken Tone
Alarm sound

- Wailing tone

Fire sound

- Two tone sound

Night Setting

- Soft Clicking

Chime

- Warble

Fault sound

- Fast Broken Tone

Error Tone

- Buzz

LIGHT INDICATORS

CONDITION

ON/CONTINUOUS

OFF

SLOW FLASH

QUICK FLASH

OPEN

Unset

System Set Waiting for Blue Key

Chime Mode

FAULT

Setting Fault

Ok

System Fault

Activation

NO LINE

Refer to Communicator Section

NO MAINS

No Mains Power

Ok/Set

Mains Restored/Fail 1Hr

TAMPER

Standing Tamper Fault

Ok

Panel/Bell Lid Tamper

Zone/RKP Tamper

ENGINEER

Engineer On Site

Ok

Engineer Needed

Service Needed

ZONES 1-10

Zone in Fault

Ok

Zone Omitted

First To Alarm

Содержание RS64

Страница 1: ...R S 6 4 I N T R U D E R A L A R M C O N T R O L PA N E L U S E R M A N U A L 2 3 1 5 6 4 8 9 7 0 7702 1783 VERSION 1 17...

Страница 2: ...d Date 9 Chime Suite 9 Part Set Suites 9 Testing 10 Sounder Test 10 Walk Test 10 Light Test 11 Remote Communication 11 Remote Reset 11 Miscellaneous 12 Installer s Specification Inside Back Cover Note...

Страница 3: ...system and this means that he she has access to more functions than the General User To operate your RS64 the Installation Engineer will need to provide you with at least one of two different types of...

Страница 4: ...ne pulsed on and off slowly Exit sound Solid tone Tamper sound Fast Broken Tone Alarm sound Wailing tone Fire sound Two tone sound Night Setting Soft Clicking Chime Warble Fault sound Fast Broken Tone...

Страница 5: ...erate when the system is set your installation may include other Zones which operate on a 24 Hour basis e g a Zone with a Panic Button Full Set You will need to use Full Set when leaving the protected...

Страница 6: ...area you will start the Entry Timer and the Entry Tone a slowly broken Exit Tone will sound You must then proceed directly to the nearest Remote Keypad You will also start the Entry Timer if you use t...

Страница 7: ...udible warning from the Guard Zones including Door Contacts when the system is Unset This is useful when the premises are occupied and you wish to be notified if other persons have entered the buildin...

Страница 8: ...tted zones Note When using Zone Omit followed by PART zones which would have been automatically omitted by the Part Set Suite see Programming section will have to be manually omitted To use Zone Omit...

Страница 9: ...to delete the code If zone lights 1 4 constant enter new code Press 4 numbered keys for new code the lights will extinguish one at a time Press ENTER to submit the new code If Warble sounds code is a...

Страница 10: ...rent 4 Digit Code User Codes To enter or change 4 digit User Codes Select Opcode 41 for User Code 1 42 for User Code 2 43 for User Code 3 44 for User Code 4 45 for User Code 5 46 for User Code 6 47 fo...

Страница 11: ...Press ENTER Warble sound indicates time date set Chime Suite To program zones to be included when Chime Mode is selected by a User Select Opcode 15 Zone lights lit show zones which are EXCLUDED from...

Страница 12: ...e light if fitted Select Opcode 60 Press numbered key 1 4 to test required sounder see table below Press key again to end test Press other numbered keys 1 4 as required Press RESET to terminate the te...

Страница 13: ...number sequence e g 1234 Telephone the Alarm Receiving Centre with the number A new 4 digit Reset Number will be given in return e g 5678 Press numbered keys to enter the Reset Number System will res...

Страница 14: ...while the system was Set Event Log The RS64 has an internal Event Log with its own Time and Date system This can be read by your Installation Engineer using a Portable Printer plugged into the Control...

Страница 15: ......

Страница 16: ...2 3 1 5 6 4 8 9 7 0...

Отзывы: