Operation
Operating instructions
52
10.3
Switching on the system
Possible damage to the system!
Only turn the main switch on the control panel if the Production rotary switch is in the
Stop position.
On the control panel, turn the Production rotary
switch to the Stop position.
On the control panel, turn the main switch to
the I = ON position.
The power supply is turned on.
The display on the PLC (1) shows the following
message:
Selecting the operating mode
On the control panel, turn the ECA rotary switch
to the Anolyte & Catholyte position and, after
the production values have levelled off, adjust
the flow rate to 40 L / h (see details on this
procedure below).
Anolyte and Catholyte are produced at a rate of
20 L / h.
or
Turn the ECA rotary switch to the Anolyte
neutral position and, after the production values
have levelled off, adjust the flow rate to 30 L / h.
Only Anolyte neutral is produced.
Sterisol
v1.0
Anolyte Error
Pumpe1
Nx 1