38
SECTION 7
7.1
GENERAL
1.
Maximum range:
16 Nautical Miles
2.
Minimum range:
Less than 25 m on the 0.125 NM range
3.
Range scales:
Range
Number of
Range ring
(NM)
Rings
Interval(NM)
0.125
2
0.0625
0.25
2
0.125
0.5
2
0.25
0.75
3
0.25
1.0
4
0.25
1.5
6
0.25
3.0
6
0.5
6.0
6
1.0
12.0
6
2.0
16.0
4
4.0
4.
Range discriminations: Less than 25 m
5.
Range ring accuracy:
Better than
±
0.9% of maximum range of
the scale in use, or 8 m, whichever is the
greater.
6.
Bearing accuracy:
±
1 degree
7.
Display device:
LCD: 115
×
86.4 mm (320
×
240 dots)
8.
Environmental conditions:
Scanner unit
Temperature
−
15
℃
to
+
55
℃
Humidity
Up to 95% at 35
℃
Display unit
Temperature
−
1
0℃ to +
50
℃
(Except LCD)
0
℃
to
+
50
℃
(LCD)
Humidity
Up to 95% at 35
℃
SPECIFICATIONS