3 – 29
3.3
To set the radar alarm zone
Procedures
1. Press the
GZ
MENU
key to open RADAR ALARM menu.
2. Press the
3
key to select "RADAR SECTOR ZONE".
3. Pressing the
ENT
key clears the menu and displays the radar screen.
4. Turn the EBL and VRM controls to set the radar alarm range and press
the
ENT
key.
Use EBL1 to set the originating point of the angle, EBL2 to set the end point of the
angle or VRM1 to set the range.
Note
●
The width of the radar alarm range is fixed.
Do not use the floating EBL for EBL2 being set.
Motion for radar alarm set zone
◎
There are two modes, namely, "IN" mode in which an alarm goes off when a target enters the set circular
radar alarm zone and "OUT" mode in which an alarm goes off when a target goes out of the zone.
◎
The radar alarm set zone is displayed only in the radar transmission mode. Note that it is not displayed
in the standby mode.
To set the alarm mode
Specify whether to output an alarm when a target enters or goes out of the radar alarm set zone.
Procedures
1. Press the
GZ
MENU
key to open RADAR ALARM menu.
2. Press the
2
key to select "RADAR ALARM MODE".
3. Press the
2
key to select "IN" or "OUT".
4. Press the
ENT
key to confirm the setting.
Exit
5. Press the
GZ
MENU
key.
Содержание JMA-7710-6
Страница 1: ......
Страница 2: ......
Страница 20: ...XVIII ...
Страница 22: ......
Страница 30: ...1 7 1 4 Fig 1 2 Outline Drawing of Scanner Unit Type NKE 1056 6M MASS APPROX 41 O UNIT mm ...
Страница 31: ...1 1 8 1 4 Fig 1 3 Outline Drawing of Scanner Unit Type NKE 1056 9M MASS APPROX 47 O UNIT mm ...
Страница 32: ...1 9 1 4 Fig 1 4 Outline Drawing of Display Unit Type NCD 3901 2 MASS APPROX 63 O UNIT mm hood CABLE INLET 25 8 ...
Страница 34: ...1 11 1 5 Fig 1 5 General System Drawing of Radar Type JMA 7710 6 ...
Страница 35: ...1 12 1 5 1 Fig 1 6 General System Drawing of Radar Type JMA 7725 6 ...
Страница 36: ...1 13 1 5 Fig 1 7 General System Drawing of Radar Type JMA 7725 9 ...
Страница 48: ...2 7 2 1 Screen Readouts 3 1 2 3 4 5 7 u i o y 1 0 q 2 t w e r 0 8 4 5 6 7 8 9 0 9 6 ...
Страница 50: ...2 9 2 1 Screen Readouts with ATA 3 1 2 3 4 5 7 u i o y 1 0 q 2 t w e r 8 4 5 6 7 8 9 0 9 6 ...
Страница 99: ...3 3 38 3 3 ...
Страница 164: ......
Страница 208: ......
Страница 216: ......
Страница 217: ...7 7 1 Routine Maintenance 7 1 7 2 Maintenance of Each Unit 7 2 MAINTENANCE ...
Страница 220: ...7 3 7 2 Safety switch Fig 7 1 NKE 1055 Scanner unit Rear Safety switch Fig 7 2 NKE 1056 Scanner unit Rear ...
Страница 222: ......
Страница 276: ......
Страница 277: ...9 AFTER SALES SERVICE ...
Страница 280: ......
Страница 281: ...10 10 1 Equipment Disposal 10 1 10 2 Disposal of Used Batteries 10 2 10 3 Disposal of Used Magnetron 10 3 DISPOSAL ...
Страница 294: ......
Страница 298: ...Appendix 2 Circuit Diagram of Radar Type JMA 7710 6 and JMA 7725 6 9 ...
Страница 299: ...Appendix 3 Terminal Board Connection Diagram of Radar Type JMA 7710 6 ...
Страница 300: ...Appendix 4 Terminal Board Connection Diagram of Radar Type JMA 7725 6 9 ...
Страница 301: ...Appendix 5 Primary Power Supply System Diagram of Radar Type JMA 7710 6 and JMA 7725 6 9 ...
Страница 302: ...Appendix 6 Internal Connection Diagram of Scanner Unit Type NKE 1055 ...
Страница 303: ...Appendix 7 Internal Connection Diagram of Scanner Unit Type NKE 1056 ...
Страница 304: ...Appendix 8 Internal Connection Diagram of Display Unit Type NCD 3901 2 ...
Страница 306: ...I I I I I I I I I I I I Appendix 9 2 Power Supply Connection Diagram of Display Unit Type NCD 3901 2 CBD 1448 2 2 ...
Страница 308: ...Appendix 10 NSK Log Selection Switches of Display Unit Type NCD 3901 2 ...
Страница 309: ...Appendix 11 Setting Table of the Speed Log Select Switches of Display Unit Type NCD 3901 2 ...
Страница 312: ......
Страница 313: ......
Страница 314: ......