The NXU-2A audio input is 47K ohm, balanced. It can be used as an unbalanced input by
grounding one half of the balanced pair and connecting the single-ended input to the remaining
half. The use of balanced inputs and shielded cables is recommended for superior immunity to
noise.
The audio input will accept signal levels from –30 to +11 dBm. Internal circuitry is used to
amplify or attenuate this input as necessary to optimize the level to the DSP. The signal level is
adjusted by the IN LVL potentiometer accessible from the rear panel. The input is set to 0
dBm when shipped. This means the IN LVL potentiometer is adjusted so that an audio input of
0 dBm provides the correct level to the DSP circuitry.
3.7.2
Audio Input Test Point
Access to an audio test point, TP1, is provided via the rear panel so the actual audio signal
voltage applied to the A/D converter can be measured with an AC voltmeter. The correct level
for best operation as measured at TP1 is about 0.2V or –12dBm (600 ohm reference.)
3.7.3
Audio Output
The audio output from the NXU-2A is a low impedance (10 ohm) unbalanced AC coupled
output. The output level is adjusted by the OUT LVL potentiometer accessible from the rear
panel. This output provides a 0 dBm nominal level; +15 dBm clipping into a 600 ohm load.
The audio output will supply signal levels from –30 to +11 dBm.
3.7.4
COR Input
The COR input to the NXU-2A is a high impedance input and can be programmed to be active
high or active low. In the active low configuration the input is pulled up to +5V DC internally
through a 47K ohm resistor. In the active high configuration the input is pulled down to ground
through a 22K ohm resistor. The logic threshold is 2.5V DC nominal, and the input is protected
from momentary surges up to +100 V DC.
3.7.5
AUX Inputs
The AUX inputs (AUX IN0 and AUX IN1) are high impedance inputs, and are always active
low. They are pulled up to +5V DC internally through a 47K ohm resistor. The logic threshold
is 2.5V DC nominal, and the input is protected from momentary surges up to +100 V DC.
3.7.6
PTT Output
The PTT output from the NXU-2A is an open drain type. It can sink up to 100 mA of current,
and can withstand open-circuit voltages up to +60V DC. In order to avoid conflicts with
internal pull-up resistors on the PTT lines of some radio equipment, there is no internal pull-up
resistor on the NXU-2A PTT output.
3.7.7
AUX Outputs
The AUX outputs from the NXU-2A (AUX OUT0 and AUX OUT1) are open drain types.
They can sink up to 100 mA of current, and can withstand open-circuit voltages up to +60V
DC. These lines are pulled up to +5V DC through a 47K ohm resistor.
Содержание NXU-2A
Страница 12: ...NXU 2A Operations Manual 1 6 Interoperability Now This Page Left Intentionally Blank...
Страница 16: ...NXU 2A Operations Manual 2 4 Interoperability Now Figure 2 1 Outline Dimensions...
Страница 17: ...NXU 2A Operations Manual Interoperability Now 2 5 Figure 2 2 Control and Connector Locations...
Страница 54: ...NXU 2A Operations Manual 7 2 Interoperability Now This Page Left Intentionally Blank...