NXU-2 Operations Manual
JPS Communications, Inc.
5-1
5 NXU-2 Troubleshooting
The following table may be used to troubleshoot any problems you may encounter during
installation or operation of the NXU-2.
Table 5-1
Troubleshooting
Symptom:
Possible Causes:
Main Power LED is not illuminated
Check that AC adapter is firmly plugged in
If user supplied power plug, check for proper
voltage, current, and polarity per Section 2.6
Power Requirements.
Cannot place the unit into Command Mode as
outlined in Section 3.3
Check RS-232 connections
Verify terminal settings: 9600 baud, 8 data
bits, 1 stop bit, no parity
(
Note: if you have previously used Command
Mode to set the serial port baud rate to a
value different than 9600 then you must use
the new baud rate to enter Command Mode
.)
Verify that no flow control, either hardware or
software, is being used in your terminal
program.
Make sure you wait at least 5 seconds, and
then type +++ (three plus signs) within 1
second.
Settings made in Command Mode do not
appear to take effect.
You must issue a SAVE command after
making changes in order to save the new
settings and restart the NXU-2.
Client and Server units are properly
configured and online but LINK ACTIVE is
not on.
Verify that both the Client and Server NXU-2
units are “visible” on the network by
“pinging” their IP addresses from a network-
connected computer.
Verify that the Server’s IP address has been
programmed into the Client using the SRVRIP
command per Section 3.3.7 Client/Server
Selection OR
If there is not a default server programmed
into the client, verify that a manual connection
has been entered per Section 4.5 Controlling
Connections
Verify that the PORT has not been changed.
from the default value of 1221, or if it has,
make sure the PORT value is the same on both
Client and Server.
Содержание NXU-2
Страница 12: ...NXU 2 Operations Manual 1 6 JPS Communications Inc This Page Left Intentionally Blank ...
Страница 16: ...NXU 2 Operations Manual 2 4 JPS Communications Inc Figure 2 1 Outline Dimensions ...
Страница 17: ...NXU 2 Operations Manual 2 5 JPS Communications Inc Figure 2 2 Control and Connector Locations ...
Страница 22: ......
Страница 52: ...NXU 2 Operations Manual 7 2 JPS Communications Inc This Page Left Intentionally Blank ...