4
transducer) is highly sensitive. Keep this important component clean and treat it with care. Do not touch the nebulizer while unit is operating, as possible burns
could result. Do not touch the nebulizer with fingers. Any residues on the metal will reduce mist output.
COMPONENTS
1. Tank’s handle
2. Adjustable distributor of vapour
3. Removable transparent tank
4. Switch ON/OFF
5. Tank’s cap
6. Base
7. Nocturnal light relax/
operating indicator
8. Red led: indicator of empty tank
9. Knob for regulation of jet
OPERATING INSTRUCTIONS
Remove the water tank from the base and turn it upside down.Turn the filling cap counter clockwise. Fill the tank with clean, cool, tap water or distilled
water and screw the filling cap firmly. Place the water tank back on the unit and allow a few minutes for the water to fill the reservoir. Note: too cold water
may temporarily reduce the output; too hot water can damage the nebulizer (ultrasonic transducer). Always position the product on a flat level and stable
surface. Plug the product. Turn the instrument on with the switch positioned on the back of the product.
The light indicator/relax light switches on, indicating that the humidifier is working. To set the vapour’s volume only turn the specific knob from the left
to the right. When the humidifier is working it is important to keep the door open (see “notes about humidity”). When the product is working in condition
of full tank and maximal distribution of the vapour jet, it has an endurance of about 12 hours. Thanks to the detector provided for the purpose, when the
water in the tank has dried up, the product goes off automatically and the red led goes on.
Pay attention: before filling the tank always switch the product off and unplug it.
CLEANING AND CARE
Before going on cleaning the product, put the switch on OFF position and unplug it. Never use detergents or aggressive sponges. Before replacing the
humidifier in its box always clean and dry it. If you will not use the humidifier for a period of time, drain any water in the tank and clean the unit. Never dip
the product into water and do not let the water to penetrate into the air inlet or into other opening. After every utilization wash the tank and the distributor
nozzle with warm water. Clean externally the product with a soft cloth and/or with a non-aggressive
detergent. Attention: never dip the unit into water. To clean the tank, never use detergent that could damage the product. In case of formation of limestone,
to clean deeply the product it is suggested to fill the tank with vinegar diluted with water and let it work for at least one hour, then rinse accurately.
To avoid growth of alga or bacteria it is suggested to not leave the product in water longer than one day.
NOTE ABOUT HUMIDITY
It is advisable to keep the humidity level at about 30 to 50%.Too dry air, caused by heating is harmful for the respiratory system. Restoring the right degree
of humidity helps to have a comfortable and healthy environment.
The humidity level will vary from room to room and according to the room conditions. In cold season, in windows and even in walls you can find some
fog or frost, because of the excessive indoor humidity. If this occurs, it is advisable to reduce the mist intensity level. Too much humidity in the room may
allow the growing on surfaces of bacteria and fungi. Collected moisture may also damage furniture and walls, especially wallpaper. To avoid too much
humidity, especially in a small room, leave the room door open and adjust the mist intensity control to the correct level.
TECHNICAL FEATURES
- Ultrasound technology, cold vapour
- Adjustable distributor of vapour
- Knob for regulation of jet
- Nocturnal light relax
- Red led: indicator of empty tank
- Security detector of water level, with automatic putting out when tank is empty
- Endurance if working with maximal distribution of vapour: about 12 hours
- Maximal intensity of vapour emission: 5.5 ml/m
- Removable tank’s capacity: 3.8 litres
- Power supply: 220-240V~50Hz
- Power: 33W
Specifications and designs are based on the latest information available at the time of printing and subject to change without notice.