4
Jøtul GZ
550
DV II
Specifications
Input Rates
Natural Gas
28,000 BTU/hr. maximum input
16,000 BTU/hr. minimum input
28,000 BTU/hr. maximum input
15,500 BTU/hr. minimum input
IIIII
MIN
MAX
Natural Gas:
5.0 WC (1.24 kPa) 11.0 WC (2.74 kPa)
Propane:
12.0 WC (2.98 kPa) 14.9 WC (3.71 kPa)
MIN
MAX
Natural Gas:
1.2 WC (.29 kPa)
3.8 WC (.94 kPa)
Propane:
2.9 WC (.72 kPa) 11.0 WC (2.74 kPa)
Jøtul GZ
550
DV II Acadia
Direct Vent Gas Fireplace
Manufactured and Distributed by:
Jøtul North America
Gorham, Maine U.S.A.
Test Standards
This appliance complies with
National Safety standards and
is tested and listed by Intertek
Testing Services of Middleton,
Wisconsin to ANSI Z21.88-2005,
ANSI Z21.88a / CSA 22.3a - 2007,
CAN/CGA 2.17-M91, and CSA P.4.-01.2.
Jøtul AS
Fredrikstad, Norway
Suggested Tools for
Installation and Service
• External regulator (for Propane only)
• Piping which complies with local code
• Manual shutoff valve - T-Handle in MA
• Sediment trap - if required by code
• 10mm open end wrench
• 1/2”, 7/16” open end wrench
• Phillips head screwdriver
• Flat head screwdriver
•Tee joint
• Pipe wrench
•Pipe sealant
• 1/4” nut driver
•Torx T20 screwdriver
• Gloves
•Safety glasses
• Leak test solution
•Power Drill
• Reciprocating Saw
Accepted For Use
City of New York Dept. of Buildings
M.E.A. No. 369-00-E
Jøtul North America, Inc.
f i r e - p a r t s . c o m