background image

20

Jøtul GZ 

550

 DV II

Brick Panel Assembly

Install the optional 155805 Brick Panels before
placing the Logset. Place the panels in position in
the order as numbered in fig. 37.  No fasteners or
tools are required.

Figure 37.   Panel installation order.

Open the lower control panel and locate

the two frame latches under the firebox floor. See
fig. 38. Pull the latch handle forward to disengage
it from the bottom of the glass frame. You can
then pull the frame out and up off of the three
retainer tabs at the top of the firebox opening. Set
the Glass Frame out of the way.

These parts are not

fastened. Simply lift them out of the firebox.

Set the bottom edge of

each side panel on the Burner Skirt and against
the firebox wall. Push the panel forward against
the front lip of the firebox opening. See fig. 39.

 Orient the panel so

that the beveled edge is on top and the mortar
joints align with those on the side panels. Set the
bottom edge on the shelf above the restrictor
adjustment slots at the back of the firebox. The
panel should fit snugly between the two side
panels. See fig. 40.

This will also be a

snug fit. Set the panel up high and then carefully
lower it to seat its lower edge against the top of
the other rear panel. The side panels will hold it in
place.

Left Side

Panel,

220997

Right Side
Panel,
220996

Lower Rear Panel,

220030

Upper Rear Panel,

220031

4

3

2

1

Figure 38.  Glass Frame latch locations.

Pull Frame Latches to

Release Frame

Figure 40. Install Lower Rear Panel.

Bevelled Edge

Figure 39. Install the Side Panels.

Side
Panel

Burner Skirt

f i r e - p a r t s . c o m

Содержание GZ 550 DV II Acadia

Страница 1: ...sult causing property damage personal injury or loss of life QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer l appareil Ne touchez aucum interrupteur Ne pas vous servir des t l phone...

Страница 2: ...BE INSTALLED AND MAINTAINED BY A QUALIFIED SERVICE AGENCY IN THE COMMENWEALTH OF MASSACHUSETTS THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER DO NOT ATTEMPTTO ALTER OR MODIFYTHE CO...

Страница 3: ...cement 26 Service Log 27 Illustrated Parts Breakdown 28 Replacement Parts List 29 Accessories 30 Lighting Instructions Back Cover Unpacking the Fireplace 1 Before you remove the carton remove the cast...

Страница 4: ...fety standards and is tested and listed by Intertek Testing Services of Middleton Wisconsin to ANSI Z21 88 2005 ANSI Z21 88a CSA 22 3a 2007 CAN CGA 2 17 M91 and CSA P 4 01 2 J tul AS Fredrikstad Norwa...

Страница 5: ...selon les codes ou reglements locaux ou en l absence de tels reglements selon les Codes d installation CAN CGA B149 4 DO NOT OPERATE THIS FIREPLACE IF ANY PART HAS BEEN UNDER WATER Immediately call a...

Страница 6: ...les enfants Garder les vetements les meubles l essence ou autres liquides a vapeur inflammables loin de l appareil Clothing or other flammable materials should not be placed ON or NEAR the Acadia gas...

Страница 7: ...N FL ET ON FLO O O O OOR SU OR SU OR SU OR SU OR SUR R R R RF F F F FA A A A AC C C C CE E E E E L L L L LO O O O OW W W W WER ER ER ER ER T T T T THAN HAN HAN HAN HAN T T T T TH H H H HE FR E FR E FR...

Страница 8: ...t rock is also considered combustible Maintain the proper clearances to the appliance to allow adequate flow of ventilation air around the fireplace Figure 8 Minimum Wall and Trim Clearance Measuredfr...

Страница 9: ...tions n Top 2 51 mm Sides Bottom 1 25 mm 4 6 Pipe 10 x 10 5 8 Pipe 11 x 11 Any horizontal run must rise 1 4 per foot Install venting in accordance with the vent manu facturers instructions Never modif...

Страница 10: ...ecific characteristics of your installation may require different settings Horizontal Termination The vent must terminate within the shaded area designated in Figs 15 and 16 Do not Do not Do not Do no...

Страница 11: ...ly recommend 12 inches particularly where windy conditions pevail H Not to be installed within 15 feet 4 5 m above a meter regulator assembly within 3 feet 90 cm horizontally from the center line of t...

Страница 12: ...local codes or in the absence of local codes with the current NFPA 70 National Electrical Code or CSA C22 1 Canadian Code A three prong grounding power supply plug is included for protection against...

Страница 13: ...with the finished surface of the wall facing The stud braces allow approximately 2 inches of forward adjustment to accommodate most any facing thickness Secure the braces to the enclosure frame 5 Com...

Страница 14: ...where flexible gas lines are not permitted use the 3 8 iron fitting to make the connection at the left side of the Control Valve See Figures 25 and 26 Secure all joints tightly using appropriate tools...

Страница 15: ...T MUST BE INSTALLED BY AN AUTHORIZED SERVICE TECHNICIAN IN ACCOR DANCE WITH THE MANUFACTURER S INSTRUCTIONS AND ALL CODES AND REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION THE INFORMA TION STICKER...

Страница 16: ...t is included for conversion to Propane use if desired Check the identification label on the Control Valve to confirm that the correct fuel is used Cet equipement de conversion sera installe par une a...

Страница 17: ...tter Wingnut Pull Frame Spring Latch to release Air Shutter Burner Tube Figure 30 Move shutter forward to disengage the burner tube assembly FROM WITHIN THE FIREBOX disengage the Pilot Hood by releasi...

Страница 18: ...tor to valve body Apply LABEL A to the cabinet floor so that it may be seen by anyone servicing the fireplace Apply LABEL B to the Rating Plate in the space provided apply gas to the system and check...

Страница 19: ...OTHER WIRES See Figure 34 At the thermostat the two wires should be connected to the two connections screw on the thermostat base plate per the manufacturer s instructions For thermostatic function p...

Страница 20: ...urner Skirt and against the firebox wall Push the panel forward against the front lip of the firebox opening See fig 39 Orient the panel so that the beveled edge is on top and the mortar joints align...

Страница 21: ...Cross over Log 5 with the pin in the Rear Log Fig 42 Set the Cross over Log across the top of the lower end of the Front Log 4 as illustrated 6 6 6 6 6 Spread a layer of ember stones evenly over the...

Страница 22: ...oshow thewinter scene Note BlueBlackPanelisenamelledononesideonly 5 5 5 5 5 Hang Hang Hang Hang Hang the C the C the C the C the Cen en en en enter Pla ter Pla ter Pla ter Pla ter Plate in position te...

Страница 23: ...control valve This valve provides easy adjust ment of the flame height appearance and heat output To adjust the flame between the HI and LO setting rotate the HI LO knob located in the center of the...

Страница 24: ...d to the new setting Retighten the locknut when the desired flame pattern is established 3 Reassemble the fireplace including glass assem bly Allow the fireplace to burn 15 20 minutes on the HIGH sett...

Страница 25: ...y allowing plenty of fresh air to circulate through the area Condensation may develop on the glass upon each lighting of the appliance This fog will disappear as the glass heats Keep the controls and...

Страница 26: ...east annually Examine the ribbon gasket for signs of deterioration and make sure the gasket has a positive seal Replace the gasket if necessary Refer to the replacement parts list on page 28 Glass Pan...

Страница 27: ...____________________________ SERVICE LOG Third Year Name of Technician________________________ Company Name____________________________ Date of service_____________________________ Work Per formed____...

Страница 28: ...7 28 29 30 31 32 33 34 35 37 38 39 40 36 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 108 84 85 86 87 88 89 90 91 92 93...

Страница 29: ...rround Leg Right Blue Black 10395727 Surround Leg Right J tul Iron 10395785 72 Surround Leg Left Matte Black 10395992 Surround Leg Left Blue Black 10395927 Surround Leg Left J tul Iron 10395985 73 Han...

Страница 30: ...ersion Kit LP 155611 Fuel Conversion Kit LP 155594 Fuel Conversion Kit NG 155595 Wall Thermostat 750003 Remote Control 129706 Steel Rectangular Matte Black 154964 Steel Arch Matte Black 154965 Brushed...

Страница 31: ...part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 1 1 1 1...

Страница 32: ...the installation it is important that the these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in specificatio...

Отзывы: