Figure 50. Proper flame pattern.
Air Shutter Adjustment
1. Open the Lower Grill panel and locate the Air
Shutter adjustment stem extending down from
the right side of the firebox floor. See figs. 49.
2. Loosen the locknut and push the stem BACK (to
the rear of the firebox) to open the air inlet
increasing airflow into the burner. Push the stem
FORWARD to decrease the air inlet. Make adjust-
ments in 1/8” (3 mm) increments and allow time
for flame pattern to respond to the new setting.
Retighten the locknut when the desired flame
pattern is established.
3. Reassemble the fireplace including glass assem-
bly. Allow the fireplace to burn 15 -20 minutes on
the HIGH setting, observing the flame continu-
ously.
4. If the flame appears weak, slow, or sooty, repeat
the process described above until the flame is as
desired.
Air Inlet Settings
Natural Gas - 1/4” open
Propane - 1/2” open
Run the fireplace for a minimum
of 15 to 20 minutes to produce an accurate
representation of the flame appearance. This
warm-up should be done before and between
any air shutter adjustment.
Air Shutter Adjustment Stem
Figure 49. Air Shutter adjustment location.