Specifications

Input Rates

Natural Gas 

  38,000 BTU/hr. maximum input 

21,900 BTU/hr. minimum input

Propane

 

38,000 BTU/hr. maximum input

20,000 BTU/hr. minimum input

Inlet Pressure:

            MIN.  

 

MAX. 

Natural Gas:   5.0 WC  (1.24 kPa)      7.0 WC  (1.74 kPa)

Propane:       12.0 WC   (2.98 kPa)        16.0 WC  (3.98 kPa)

Manifold Pressure:  

   MIN  

 

MAX.

 

Natural Gas:   1.2 WC  (0.29 kPa)     3.8 WC  (0.95 kPa)

Propane:         2.9 WC  (0.72 kPa)        11.0 WC (2.74 kPa)

Steady State Efficiency:  79% / NG      81.2% / LP
A.F.U.E. Efficiency:              65.2% / NG  65.4% /LP 
Piezo Ignitor / Standing Pilot 

Jøtul GI 

550

 DV / Scan 

70

i

Direct Vent Gas Fireplace Insert

Manufactured and Distributed by: 

Jøtul North America 

Gorham, Maine USA

Test Standards

This appliance complies with Na-

tional Safety standards and is tested 

and listed by Intertek Testing Services 

of Middleton, Wisconsin.

In addition, the Jøtul GI 

550

 DV 

gas fireplace insert has been tested 

and listed as a direct vent gas fireplace heater and 

listed to ANSI Z21.88-2009,  CSA 2.33-2009, 

 CAN/CGA 2.17-M91, and CSA P.4.-01.2 for Canada.

Basket Screen

 (for Cast Iron Double Doors)

 ..............#156426

Reversible Brick Panel Kit, Corduroy Blk/Gry ..............#156427

Reversible Brick Panel Kit, Antique/Border ................ #156428

Fuel Conversion Kit - NG to LP .......................................#156446

Fuel Conversion Kit - LP to NG ........................................#156447

High Altitude Adjustment Kit - LP ................................. #156451

High Altitude Adjustment Kit- NG ................................#156452

Wall Thermostat .............................................................. #750003

Remote Control .................................................................#129706

Cast Iron Surrounds

40” Wide x 30” High. (32” w/ plinth option) 

 

Matte Black Paint .......................#351053 Great Diamond

 

Blue Black Enamel  .....................#351054 Great Diamond

 

Jøtul Iron Paint ............................#351055 Great Diamond

Cast Iron Double Doors

 

Matte Black  ...............................................................#351057

 

Blue Black Enamel  ...................................................#351058

 

Jøtul Iron  ....................................................................#351059

Steel Surround Kits

Simple Surround, 44” x 32

”  ........................................ #157228

Wide Surround Panel* 

       

46 1/2” Wide x 33” High. (35” w/ plinth extensions)

        Black Powder Coat ...................................... ............  #156429

Trimmable Surround, 46 1/2” x 33”

 

Matte Black Paint ......................................................#157327

Grand Forge - 44”  x 32”  

 

Charcoal Gray  ..........................................................#156420

 

Natural Iron ................................................................ #156421

 

Black Powder Coat  ...................................................#156422

Cathedral Arch Doors & Surround w/ Screen,  44” x 32”  

 

Charcoal Gray    .........................................................#156423

 

Natural Iron .............................................................. #156424

 

Black Powder Coat  ..................................................#156425

Scan 70i Sliding Glass Panel & Surround,  44”  x 31” 

 

for 1” Riser - includes Mantel Heat Shield 

 

Black Powder Coat   ..............................................#K156442

 

Stainless Steel ........................................................#K156443

Scan 70i Sliding Glass Panel & Surround,  44” x 32” 

 

for 2” Riser - includes Mantel Heat Shield 

 

Black Powder Coat   ..............................................#K156462

 

Stainless Steel ........................................................#K156463

Accessories  

This fireplace is equipped to burn natural gas 

only. If propane gas is desired, the fireplace must 

be converted for use with propane. Install the 

LP Conversion Kit included with the fireplace ac

-

cording to the instructions in this manual.

* Custom sizes availabLe. See your dealer for details.

Содержание GI 550 DV

Страница 1: ...ce QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer l appareil Ne touchez aucum interrupteur Ne pas vous servir des t l phones se trou vant dans le b timent o vous trouvez Appelez imm...

Страница 2: ...mpletion of the installation Suggested Tools for Installation and Service External regulator for Propane only Piping which complies with local code Manual shut off valve T Handle required in Massachus...

Страница 3: ...engage it from the Glass Frame Latch Release Tool Left Latch Release Unpacking the Fireplace A Miscellaneous Hardware Kit is packed within the right side compartment of the firebox It contains Install...

Страница 4: ...onversion Kit LP to NG 156447 High Altitude Adjustment Kit LP 156451 High Altitude Adjustment Kit NG 156452 Wall Thermostat 750003 Remote Control 129706 Cast Iron Surrounds 40 Wide x 30 High 32 w plin...

Страница 5: ...vir de cet appareil s il a ete plonge dans l eau completement ou en partie Appeler un technicien qualifie pour inspecter l appareil et rem placer toute partie du syste me de controle et toute commande...

Страница 6: ...for use with 3 Type B vent pipe components or a Listed Flexible gas liner See the Appendix on page 28 for a complete list of vent pipe manufacturers whose prod ucts are approved for use with this appl...

Страница 7: ...he height appropriate to your installation require ments Figure 2 Firebox dimensions Figure 3 Minimum fireplace dimensions GI 550 DV A Opening Width 34 1 2 876 mm with leveling brackets 36 914 mm B Op...

Страница 8: ...least 16 forward of the firebox glass panel with the following exception Cast Iron surrounds without Plinth the hearth pro tection must extend 36 x 18 See fig 4 Table 1 Fireplace Facing Options J tul...

Страница 9: ...nry or zero clearance flue CANNOT be used to vent any other appliance Flexible liner components may not be exposed in any living space Installation of any components not manufactured or approved by J...

Страница 10: ...the unit and will carry the exhaust gases to the outside of the house This exhaust liner must be directly connected to the unit and run the full length of the chimney See fig 6 The other 3 liner will...

Страница 11: ...uld be cut or pried off 2 Remove the damper assembly This includes the damper blade handle and any linkage Two 3 liners must be able to pass through the damper area 3 Remove any fire screen or door as...

Страница 12: ...ebox where it will be readily seen should the insert be removed Cutting of any sheet metal parts on a solid fuel fireplace is prohibited If the factory built fireplace has no gas access hole s provide...

Страница 13: ...st not block or seal any venti lation openings on the prefabricated fireplace Vent Connection The Vent Collar Plate located on top of the cabinet is removable to ease connection of the vent liners in...

Страница 14: ...Turn on gas supply and test for gas leaks using a 50 50 soapy water solution or a gas detector Never use an open flame to check for leaks A T HANDLE GAS SHUT OFF VALVE IS RE QUIRED IN MASSACHUSETTS I...

Страница 15: ...ing its individual manual gas shut off valve gas cock during any pressure testing of the gas supply piping system that is equal to or exceeds pres sures of 1 2 psig 3 5 kPa Inlet Pressure MIN MAX Natu...

Страница 16: ...ng a 4 mm hex key unscrew the pilot orifice counterclockwise Replace with the orifice from the kit Tighten new orifice securely into the base of the pilot assembly Replace Pilot Hood by pushing it int...

Страница 17: ...rubber gasket Thoroughly tighten new regulator to valve body 8 Apply the Conversion Labels Apply LABEL A to the cabinet floor so that it may be seen by anyone servicing the fireplace Apply LABEL B to...

Страница 18: ...lugged directly into a properly grounded three prong receptacle DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG ALWAYS DISCONNECT THE POWER SUPPLY BEFORE SERVICING THE BLOWER Wall Thermostat In...

Страница 19: ...ent the rear panel to align with the brick courses on the Side Panels as shown in fig 20 Place the panel against the back wall of the firebox resting on the log shelf as in fig 21 4 Install the Side P...

Страница 20: ...skirt against the back of the firebox as shown in fig 24 2 Set the Lower Left and Right logs in place on the burner plate pegs as shown in fig 25 3 Set the three upper logs on the appropriate pegs as...

Страница 21: ...s described in the lighting instructions located on the fireplace s rating plate and back cover of this manual 2 PILOT FLAME The pilot flame should be steady not lifting or floating The flame should b...

Страница 22: ...anger brackets that engage with the hanger tabs on the firebox Hanger Brackets Surround Assembly Each of the surround assemblies and front facings is completely assembled at the factory No further as...

Страница 23: ...ways follow the Lighting Instructions located on the inside Back Cover of this manual and also on the Rating Plate located in the burner controls compartment 2 For the first several hours of operation...

Страница 24: ...tube Glass Care Clean the glass as necessary Wipe the surface with a clean dampened soft cloth Follow with a dry soft towel Take care not to scratch the glass surface Scan 70i Sliding Glass Panel Car...

Страница 25: ...es using a blanket or towel 3 The glass panel is held in place by four retainer clips Use a screwdriver to carefully pry these up off the edge of the glass retaining walls See fig 35 4 Remove the old...

Страница 26: ...26 138727_Rev_F 8 9 11 Universal GI 550 Illustrated Part Breakdown DV Figure 37 Part Identification...

Страница 27: ...0 Cabinet Top 221737 41 Gasket Vent Adaptor 222281 42 Vent Connector Assembly 222259 43 Gasket 3 Adaptor 129677 44 Heat Shield Top Firebox 222415 45 Relief Door 222432 46 Burner Top Plate 221749 47 Bu...

Страница 28: ...ch cap Place the switch in the OFF position 5 Run the receiver wires out the back of the switch box and connect the leads to the TH and TH TP terminals on the valve DO NOT DISCONNECT ANY WIRES FROM TH...

Страница 29: ...associated with the repair of gas controls plumbing burners log set or sheet metal firebox beyond the warranty period 5 Damage caused by unauthorized modification use or repair 6 Damage to enameled s...

Страница 30: ...erformed ____________________________ _________________________________________ _________________________________________ Your fireplace insert has a unique serial number stamped on the rating plate w...

Страница 31: ...trol which has been under water 3 Access the lower controls 4 Depress gas control knob slightly and turn clockwise to OFF Do not force 8 Push in control knob all the way and hold in Im mediately light...

Страница 32: ...nning the installation it is important that the these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in specif...

Отзывы: