background image

31

induction heating

Induction Heater JH400

The following troubleshooting table is useful when tracing the faults . The table lists the 

most common faults and their possible causes and there might be additional faults and 

possible causes other than those listed in the table .

Troubleshooting table

Fault

Possible cause

Action

No power to the heater .

The heater is not plugged 

into the wall outlet . 

 

 

No voltage supply . 

 

 

 

Loose connections .

Plug the heater to the wall outlet . 

 

 

 

Check that there is power in the 

wall outlet and check if the mains 

protection has tripped . 

 

Make sure that there are 

no loose connections in the 

electrical plug and the wall outlet .

Main power is sufficient, but the 

heater doesn’t operate .

The ground breaker 

operator has tripped .

Switch on the ground breaker 

operator .

Water leakage between the 

inductor handle and the inductor 

head .

The gasket is damaged . Change or tighten .

The black cable cover is broken The cable cover has 

been damaged .

Please contact JOSAM AB 

service personnel .

The red LED “Over 

temperature” is lighted and the 

heater is turned off

The temperature of the 

electronics is too high

Let the heater cool down or 

change the water . Once the 

heater has cooled down and 

the LED is no longer lighted, the 

heater is ready to use .

The red LED “Water flow” is 

lighted and the heater is turned 

off .

The flow of cooling water 

is not correct

The water level is too low – fill up 

with fluid.
The coarse filter of the pump is 

blocked – clean the filter.
One of the water hoses is 

blocked – Try cleaning with 

compressed air .

The 2 red LEDs flash 

simultaneously .

An unexpected error 

occurred .

Release and press the trigger 

again . If the error still occurs 

switch the heater off and on 

again by switching the main 

breaker . If the problem still 

remains contact JOSAM service 

personnel .

Содержание JH400

Страница 1: ...T 98 1 1201 JH400 Instructions for Use and Safety Regulations for Induction Heater JH400...

Страница 2: ...indicator 22 Trigger activated 22 Using the heater 23 Service and maintenance 24 Regular checks 24 Every day before use 24 Monthly inspection 24 Yearly inspection 24 Cleaning 25 Checking the residual...

Страница 3: ...e instructions in this manual can cause personal injury and or machine damage JOSAM AB can in no way be held responsible for intentional or unintentional damage and consequent unlimited loss of profit...

Страница 4: ...t has not been altered or rebuilt without approval from JOSAM AB genuine JOSAM AB spare parts are used in any repairs operation and maintenance has been carried out according to the instructions in th...

Страница 5: ...appropriate safety regulations The equipment illustrated in the manual may be changed without prior notice The contents in this publication can be changed without prior notice This publication contain...

Страница 6: ...ed to heat all magnetic materials conductors by concentrating a powerful magnetic field at the head of the inductor But the heater also works well on aluminium The magnetic field alternates at a frequ...

Страница 7: ...7 induction heating Induction Heater JH400 MARKING Name plate The name plate is placed at the rear of JH400...

Страница 8: ...th all applicable safety aspects for this type of equipment During operation and other work it is always each individual s responsibility to consider to their own and other s personal safety The safet...

Страница 9: ...es are used in the instruction manual Important in bold type is used to indicate a possible danger that could lead to damage to the equipment and or cause environmental damage NOTE in bold type is use...

Страница 10: ...t these items from being ignited WARNING Make sure that you know where the fire extinguishing equipment is Risk for injuries WARNING If not removing paint or other chemicals before heating use a sucti...

Страница 11: ...nsibility to ensure that the equipment is inspected in accordance with applicable regulations before it is used IMPORTANT For the sake of the environ ment it is important that the equipment is dismant...

Страница 12: ...worn when using this equipment WARNING Sparks from heating could start a fire WARNING Risk of tripping on loose hoses etc WARNING All electrical modifications must be made by a qualified electrician...

Страница 13: ...13 induction heating Induction Heater JH400 Placement of safety signs The safety signs are placed at the rear of JH400 as follows...

Страница 14: ...g about 10 seconds after the trigger has been released A sensor detects the water flow and switches off the heater if the water flow is blocked JH400 is connected to earth There is a residual current...

Страница 15: ...that the equipment has been installed as specified in the instructions provided It is also the owner s responsibility to ensure that the equipment is inspected in accordance with applicable regulatio...

Страница 16: ...16 induction heating Induction Heater JH400 Installation of the wheels How to lift the JH400 Lift the JH400 in the handle and between the front and back wheel...

Страница 17: ...mp 3 Fill the water tank NOTE Do not fill up the tank entirely to allow space for the hot water to expand Fill the tank with 20 litres of fluid WARNING Do not fill the water tank with anything but Dec...

Страница 18: ...l outlet The power supply must have a ground connection and it must also be protected with a fuse as follows When using up to step 4 of the output power the supply can be protected with a 10 A fuse Wh...

Страница 19: ...uctor and a heater unit A magnetic field is concentrated in the inductor when the trigger is activated Therefore the inductor head the inductor handle the cables and the power electronics are automati...

Страница 20: ...nected to main supply Once this button is activated one or more of the yellow LED light emitting diode of the power indicator is lighted up Increase power Increase the power with one step step 1 5 Dec...

Страница 21: ...the temperature is below limit Water flow The red LED Water flow is lighted if the cooling water is not flowing correctly that is if the water pressure is too high or to low The heater will not funct...

Страница 22: ...th a green LED Trigger activated The green LED Trigger activated is lighted when the trigger on the handle is pressed This indicator tells the user that the cable to the handle is not damaged It start...

Страница 23: ...igh effect Low effect Medium effect Low effect 4 Very high effect Medium effect High effect Medium effect 5 Extremely high effect High effect High effect Medium effect Trigger Inductor head NOTE JH400...

Страница 24: ...tank If needed fill up the water tank Check that there is no water leakage between the inductor handle and the inductor head Check that the isolation is not damaged on the inductor handle Check that...

Страница 25: ...equipment Checking the residual current breaker At least once a year the residual current circuit breaker must be checked Press the test button on the residual current breaker operator at the rear of...

Страница 26: ...nductor may be hot Risk for burning injuries NOTE Use only copper paste Don t use any grease or oil NOTE Only use an inductor head supplied by JOSAM AB O ring gasket 3 Check that all contact surfaces...

Страница 27: ...o carefully lift the cover from the induction head 3 Remove the cover A keep track of the silicon washer that either sticks to the field amplifier or to the cover B 4 Remove the field amplifier by twi...

Страница 28: ...ly new heat paste to assure a good thermal contact between the field amplifier and the cooling loop 7 Fit the field amplifier tight to the induction head and place the silicon washer on the amlifier i...

Страница 29: ...ank Normally the water tank is never to be emptied But if something unexpected occurs the water tank can be emptied as follows 1 Open the front cover Loosen the straps and slide out the water tank 2 O...

Страница 30: ...operating servicing or working in the immediate area around JH400 the user should not wear or use metal objects such as watches rings keys etc Otherwise these objects could be heated by the magnetic f...

Страница 31: ...eakage between the inductor handle and the inductor head The gasket is damaged Change or tighten The black cable cover is broken The cable cover has been damaged Please contact JOSAM AB service person...

Страница 32: ...environment for repairing vehicular damages Warranty If the instructions in this manual are not followed the machine s warranty becomes null and void Recycling The machine must be recycled according t...

Страница 33: ...tection IP 21 Coolant Water Water tank volume 35 litres Installation electric mains connection Mains connection 208 240 V 1 Ph PE Frequency 50 60 Hz Fuse 16 A Requirements for the ambient conditions R...

Страница 34: ...00 Conformity with directives and standards JH400 range is designed and manufactured by Car O Liner AB which is an EN ISO 9001 14001 accredited development and manufacturing organisation The JH400 ran...

Страница 35: ...35 induction heating Induction Heater JH400 EC DECLARATION OF CONFORMITY...

Страница 36: ...ater JH400 Manufacturer JOSAM AB Box 419 SE 701 48 REBRO Sweden Telefon 46 19 30 40 00 Fax 46 19 32 03 16 E mail info josam se Internet www josam se Printed on environmentally friendly paper This page...

Отзывы: