ALARM INSTALLATION INSTRUCTIONS

The  drain  is  equipped  with  an  alarm  feature.  Alarm  occurs 
when the valve has to open too many (>100) consecutive times 
without  a  pause.  The  reason  for  this  may  be  debris  (rust) 
particles blocking the valve, outlet, or a sensor failure indicating 
a service necessity. It could also mean that your drain receives 
more condensate than it can handle. The alarm feature can be 
connected  to  an  external  alarm  device  with  its  own  power 
supply. 
1. Unscrew the connector screw and remove the cap from the 
alarm connector to connect the alarm cables to the connector 
as shown below. Caution is required as you may be working
with hazardous voltages! 

2. Connect the cable to your alarm device, any device of your 
choice can be applied i.e. a (flashing) light or alarm panel.

3. Connect your alarm device to a power supply. The alarm 

switch type is a ‘contact output switch’. An external power 

supply is required as the alarm connection point on the drain 
works like a relay switch only. 

4. Connect the power supply to the drain alarm connector to 
close the circle. Replace the connector and tighten the 
connector screw (Max. torque 1Nm). 

Make sure the gasket is

secured properly to ensure IP65 rating.

Содержание KAPTIV-CS-D-LUX

Страница 1: ...1 Installation Maintenance Instructions 7 2018...

Страница 2: ...l must employ safe engineering practices and observe all local health safety requirements regulations International users refer to regulations that prevail within the country of installation Most acci...

Страница 3: ...3 1 1 1 2 1 3a 1 3b 1 4a 1 4b 1 5 1 7 L N 1 6 1 8...

Страница 4: ...e draining point in your compressed air system and connect your drain as illustrated The use of a ball valve is advisable The use of a venting line may be required 1 4b Side inlet connection Connect t...

Страница 5: ...ing bolt Washer 4x Housing top part Housing gasket Inlet plug 2x Strainer Valve shaft Valve spring small Screw knurled washer Valve spring large Electronics compartment gasket Valve plunger Housing bo...

Страница 6: ...move the cap from the alarm connector to connect the alarm cables to the connector as shown below Caution is required as you may be working with hazardous voltages 2 Connect the cable to your alarm de...

Страница 7: ...e is not sufficient or if any other flow problem occurs a venting line must be installed to prevent an air lock Do not narrow the feed pipe when installing additional adapters or piping these may caus...

Страница 8: ...no debris left in the other parts of the drain 2 7 Use a 10mm Allen key to remove the plug and strainer Clean the strainer thoroughly Replace the strainer and plug using a 10mm Allen key 2 8 Reassembl...

Страница 9: ...9 9 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 9 2 11 2 12 2 10 2 8...

Страница 10: ...voltage options 230VAC or 115VAC or 24VAC or 24VDC See label on unit Connectors DIN 43650 B Serviceable valve Yes TEST feature Yes Environmental protection IP65 NEMA4 Integrated mesh strainer Yes Ala...

Страница 11: ...11 SERVICE CHART Date Description Name...

Страница 12: ...12 DIMENSIONS...

Отзывы: