background image

SAFETY AND PROPER USAGE

To  ensure  safe  and  enduring  performance  of  this  product,  you  must  comply  strictly  with  the  instructions  enclosed 
herein.  Non-compliance  with  instructions  or  improper  handling  of  the  product  will  void  your  warranty!  Usage  of  this 
product  in  conditions  not  specified  in  this  manual  or  in  contrary  to  the  instructions  hereby  provided  is  considered 
IMPROPER. The manufacturer will not be held liable for any damages resulting from improper use of the product.

 

SAFETY & WARNING INSTRUCTIONS

-  Observe valid and generally accepted safety rules when planning, installing and using this product.
-  Take proper measures to prevent unintentional operation of the product or damage to it.
-  Do not attempt to disassemble this product or lines in the system while they are under pressure.
-  Always depressurise the compressed air system before working on the system. 

It is important that personnel use safe working practices and observe all regulations and legal requirements for safety 
when operating  this product.  When handling,  operating or carrying  out maintenance  on  this product,  personnel  must 
employ safe engineering practices and observe all local health & safety requirements & regulations. International users 
refer to regulations that prevail within the country of installation. Most accidents, which occur during the operation and 
maintenance of machinery, are the result of failure to observe basic safety rules or precautions. An accident can often 
be avoided by recognising a situation that is potentially dangerous. Improper operation or maintenance of this product 
could be dangerous and result in an accident causing injury or death. The manufacturer cannot anticipate every possible 

circumstance,  which  may  represent  a  potential  hazard.    The  WARNINGS  in  this  manual  cover  the  most 
common potential hazards and are therefore not all-inclusive. If the user employs an operating procedure, an item of 
equipment or  a method of working  which is  not specifically recommended by the manufacturer he must ensure that 

the  product  will  not  be  damaged  or  made  unsafe  and  that  there  is  no  risk  to  persons  or  property.   

NEVER CHANGE ORIGINAL COMPONENTS WITH ALTERNATIVES

 

WARNING: 

This product can expose you to chemicals including lead, which is known to the State of California to 

cause cancer and/or birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov

Содержание KAPTIV-CS-D-LUX

Страница 1: ...1 Installation Maintenance Instructions 7 2018...

Страница 2: ...l must employ safe engineering practices and observe all local health safety requirements regulations International users refer to regulations that prevail within the country of installation Most acci...

Страница 3: ...3 1 1 1 2 1 3a 1 3b 1 4a 1 4b 1 5 1 7 L N 1 6 1 8...

Страница 4: ...e draining point in your compressed air system and connect your drain as illustrated The use of a ball valve is advisable The use of a venting line may be required 1 4b Side inlet connection Connect t...

Страница 5: ...ing bolt Washer 4x Housing top part Housing gasket Inlet plug 2x Strainer Valve shaft Valve spring small Screw knurled washer Valve spring large Electronics compartment gasket Valve plunger Housing bo...

Страница 6: ...move the cap from the alarm connector to connect the alarm cables to the connector as shown below Caution is required as you may be working with hazardous voltages 2 Connect the cable to your alarm de...

Страница 7: ...e is not sufficient or if any other flow problem occurs a venting line must be installed to prevent an air lock Do not narrow the feed pipe when installing additional adapters or piping these may caus...

Страница 8: ...no debris left in the other parts of the drain 2 7 Use a 10mm Allen key to remove the plug and strainer Clean the strainer thoroughly Replace the strainer and plug using a 10mm Allen key 2 8 Reassembl...

Страница 9: ...9 9 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 9 2 11 2 12 2 10 2 8...

Страница 10: ...voltage options 230VAC or 115VAC or 24VAC or 24VDC See label on unit Connectors DIN 43650 B Serviceable valve Yes TEST feature Yes Environmental protection IP65 NEMA4 Integrated mesh strainer Yes Ala...

Страница 11: ...11 SERVICE CHART Date Description Name...

Страница 12: ...12 DIMENSIONS...