CERT: GMK10121
Water is not hot
enough
Adjust the gas regulator and water regulator to meet your desired
temperature. To Increase temperature; turn the gas regulator control from
minimum to maximum and turn the water regulator control from
maximum to minimum.
Check source water temperature. If the source water temperature is too
cold then you may need to ‘cycle’ the water through the system back
into the source reservoir then through the appliance again to meet your
desired temperature.
Check if there is a blue flame in the ‘viewing window’. If you see a
yellow flame it could mean a breakdown in the gas regulator. Please
call Joolca Customer Service directly if this happens, do not attempt to
use it.
The unit starts
for a short
amount of time
and then shuts
off
Check your Gas Cylinder to ensure it is not empty. If using a new
cylinder; try to cycle the unit on and off by using the showerhead
switch several times to purge the air from the gas lines.
Do not expose the water heater to strong winds.
This unit activates at a sustained water pressure of 25 kPa. If your
supply water pressure is below the minimum the unit will not ignite.
SPECIFICATIONS
Model Number
PWH5L
Injector Size mm
0.62
Total NGC MJ/h
28
TPP kPa
2.75
Min. Water Pressure
25 kPa
Max. Water Pressure
900 kPa
Size mm
400 x 395 x 130
Weight
4.2 kg
This Portable Water Heater is distributed by Joolca Pty Limited
CUSTOMER SERVICE ON THIS APPLIANCE
AUSTRALIA 1300 669 500
WWW.JOOLCA.COM.AU