Trouble
Check if...
Solution
Linearity is not good Feedback lever is on the wrong setting
Readjustment zero, span adjustment
Wrong zero, span adjustment
Readjustment zero, span adjustment
Supply pressure is unstable
Replace regulator
Hysteresis is poor
Wrong setting of seat adjustment
Readjust seat adjuster
Loose connection of actuator and positioner
Tighten connection
Cam shaft is worn out
Replace cam shaft
Option
Pilot valve with output orifice
1. Hunting may occur when the positioner is attached to a small capacity actuator.In such case, use a
pilot valve having a output orifice for OUT1 and OUT2. The output orifice is removable.
2. Output orifice types. (Refer to description in chapter 4. Ordering Symbols.)
Volume of Actuator
Output orifice diameter
Ordering No.
Below 6 cubic inches
Ø 0.7
RO1
6~10 cubic inches
Ø 1.0
RO2
Over 10 cubic inches
None
3. After pulling out the O-ring from OUT1 and OUT2 port, push proper orifice and then mount the O-ring to OUT1 and
OUT2 again. When mounting the output orifice, pay attention not to let dust and others enter the port hole.