Страница 2: ...anty Contents General 3 Features 3 Specifications 3 Ordering 3 Inside View 4 Principle of Operation 4 Block Diagram of AEP 100 5 Installation 5 Example of attaching to actuator 5 Connection with feedback shaft 5 Cam attaching procedure 6 Attaching procedure of opening degree indication plate 6 Air Piping Connection 6 Electrical Wiring 7 Adjustment 7 Zero Adjustment 7 Span Adjustment 8 Auto Manual ...

Страница 3: ... response Low air consumption Easy to protect from hunting effect by using output orifice in small size of actuator Designed as Multi port type of for air tubing Easy to install air tubing connection in any direction Designed as modular structure for maintenance and repair Specifications AEP 100 Single Acting Double Acting Input Signal 1 20mA Dc below 24V 1 2 split range available Impedance 250 15...

Страница 4: ...reduces Nozzle Back Pressure with increase in gap between Flapper and Nozzle Then Spool moves upward and the Seat opens simultaneously Air pressure of OUT1 pipe is discharged to 10 Actuator As pressure in the actuator chamber goes up Actuator stem starts to rotate The movement of Actuator stem exerts force to the Feedback Spring through the Feedback Shaft connection Then the Actuator will stop at ...

Страница 5: ...ides a stamped steel bracket above right for mounting to the bottom of the positioner However the PP 100 is drilled and tapped on the side for side mounting of a custom fabricated bracket above left Connection with feedback shaft All Jomar positioners come with a standard NAMUR type spaded shaft for direct mounting to all Jomar actuators and most other brands of rack and pinion actuators manufactu...

Страница 6: ...pply the supply pressure when attaching the cam as otherwise it is very dangerous 4 When the positioner is shipped out of our plant the cam is tentatively tightened to the shaft Be sure to firmly lock the cam to the lock nut tightening torque approx 18 inch Pounds Attaching procedure of opening degree indication plate Lock the cam and then adjust the zero point and span Then fix the opening degree...

Страница 7: ...pipeline is correctly connected with the pressure supply port and OUT1 and OUT2 port 2 Check that the wires are correctly connected with the and grounding terminals 3 Check that the actuator and positioner are sturdily connected 4 Check for locking of the auto manual changeover screw of pilot valve fully tightened in the clockwise direction 5 Check that the span adjusting lever of internal feedbac...

Страница 8: ...terclockwise 3 In manual operation the supply pressure is routed directly to the actuator through output 1 4 This feature is only available for directing supply pressure through output 1 Seat Adjuster sensitivity adjustment 1 No need to adjust in the field because the Seat Adjuster Is adjusted before shipment for balanced pressure point of output pressure 2 Seat Adjuster is always used for Double ...

Страница 9: ...itioner may not operate normally 3 Do not remove the terminal cover at a dangerous position during power conduction 4 Be sure that the terminal cover and body cover are put on during the operation 5 If you leave the positioner at the operation site for a long time without using it put the cover on it so that the rain water does not enter the positioner If the atmosphere is of high temperature or h...

Страница 10: ... cam shaft Option Pilot valve with output orifice 1 Hunting may occur when the positioner is attached to a small capacity actuator In such case use a pilot valve having a output orifice for OUT1 and OUT2 The output orifice is removable 2 Output orifice types Refer to description in chapter 4 Ordering Symbols Volume of Actuator Output orifice diameter Ordering No Below 6 cubic inches Ø 0 7 RO1 6 10...

Страница 11: ...040215 Jomar Valve 7243 Miller Drive Warren MI 48092 www jomarvalve com phone 586 268 1220 fax 586 979 8315 Note Information subject to change without notice ...