Installation Manual

 - Jolywood N-type Mono-crystalline Double Glass Module

5.2.4.1

All module frames and brackets must be properly 
grounded  in  accordance  with  thappropriate 
National  Electrical  Code.  The  grounding 
conductor or grounding wire could be made with 
copper,  copper  alloy  or  other  material,  which 
should  also  be  in  accordance  with  the 
requirements of corresponding National Electrical 
Code.  The  grounding  conductor  must  be 
connected  to  he  ground  through  a  suitable 
grounding methods.

5.2.4.2

Module  could  be  grounded  with  a  grounding 
equipment listed by a third party. The equipment 
must  be  installed  in  accordance  with  the 
instructions  given  by  the  grounded  equipment 
manufacturer.

5.2.4.3

Please visit http://www.jolywood.cn/ to view the 

“Product  Catalog” link  for  detailed  grounding 

holes locations and dimensions.

5.2.4.4

The electrical contact is formed by penetrating the 
anodized  coating  of  the  aluminum  frame  and 
tightening  the  ground  screw  (together  with  the 
star washer) to an appropriate torque of 3~7N.m. 
A  properly  sized  ground  wire  (4-16mm2  copper 
core wire) should be selected and mounted under 
the connecting bolt.

Place  the  toothed  washers,  washers,  and 
grounding wires in turn, and screw the screws into 
the grounding holes to connect the two adjacent 
modules.

5.2.5   Electrical Installation 

All wiring should be performed by a qualified and 
trained  person  in  accordance  with  local 
regulations  and  procedures.  Modules  could  be 
connected  in  series  to  increase  the  operating 
voltage  by  inserting  the  positive  plug  of  one 
module into the negative plug of another module. 
Always  ensure  that  the  contact  points  are 
corrosion-resistant,  clean,  and  dry  before  wiring 
modules. If the polarities of modules connected 
wrong,  may  lead  to  irreparable  damage.  Before 

5.2.4   Installation of full frame double 

glass modules (Installation with flat 

single axis tracker)

Mounted with 4 clamps along long frame.                                                                                                                                                                                                                  
Edge Clamp: width=40-50mm, height=30mm.
A=50~100mm 
maximum test load: front ≤1800Pa  
back ≤1800Pa

The long frame uses the inner four holes (990mm) 
for bolt installation
Mounting  bracket/C-shaped  steel  perpendicular 
to the long frame     
maximum test load: front ≤5400Pa  
back ≤2400Pa

 

JW-HD108N/P 

Содержание HD108N

Страница 1: ...INSTALLATION MANUAL Jolywood N type Mono crystalline Double Glass Module M10 Double glass module HD108N P All rights reserved Jolywood Taizhou Solar Technology Co Ltd ...

Страница 2: ...tallation Installation Safety Mechanical installation and precautions Framed Bifacial Double Glass Modules installation with clamps Grounding Electrical installation Wiring Fuse Maintenance for PV Modules Module Visual Inspection and Replacement Connector and Cable Inspection Cleaning Water quality requirements Module Inspection after Cleaning Troubleshooting Technical Issues or Claims Framed Bifa...

Страница 3: ...sional knowledge and the system must be installed and maintained by qualified person with professional knowledge Please store this guide in a safe place for future reference maintenance which would also be useful when selling or disposing of the modules The module installer must inform the end customer or consumer of the above matters accordingly Jolywood reserves the right to change this installat...

Страница 4: ...by qualified person with professional knowledge Persons without authorization and relevant training should not touch modules and approach the installation area or module storage area Do not connect the positive terminal of a single module to the positive terminal of another module Please make sure that the polarity of each module or module string is not opposite to other modules or module strings P...

Страница 5: ...directly on the module during transportation Improper transportation or installation also may damage module which is excluded from the warranty Do not stand climb walk or jump on unpacked pallets of modules Always work under a dry environment ensure that all modules and electrical contacts are clean and dry before installation If it is necessary to store the modules outdoors for a certain period o...

Страница 6: ... on a relatively flat ground to avoid package damage or dumping due to ground deformation or collapse Storage requirements humidity 85 temperature range 40 50 If the modules need long distance transportation or long term storage do not remove the original packaging and keep the wrapping film and packaging carton intact If the module would be transported for a too long distance or stored for a long p...

Страница 7: ... fixed The ground needs to be flat enough to ensure package could be placed horizontally and stably Supportive tool should be used when disassembling the carton to prevent the modules from falling down 4 1 3 Wear protective gloves during unpacking to avoid injury and fingerprints on the glass surface 4 1 4 Module information could be queried from outer package please read it carefully before unpackin...

Страница 8: ... during installation Do not open the electrical connection or pull out the connector while the circuit is under load Do not touch the modules during installation unless necessary Glass surfaces and brackets may have high temperature which might lead to the risk of hazards of burns and electric shock The modules produced by Jolywood could installed landscape or portrait the influence of shading effec...

Страница 9: ...fire 5 1 9 The application level of module produced by Jolywood is Class A modules with different color should be avoided from installed in the same array or roof Mounted with 4 clamps along long frame C shaped steel parallel to the long frame Edge Clamp width 40 50mm height 30mm A 350 30mm maximum test load front 2400Pa back 2400Pa snow and wind loads depends on the way of module installed The mech...

Страница 10: ... 350 30mm maximum test load front 5400Pa back 2400Pa Mounted with 4 clamps along short frame C shaped steel parallel to the short frame Edge Clamp width 40 50mm height 30mm A 250 30mm maximum test load front 1200Pa back 1200Pa JW HD108N P JW HD108N P Mounted with 4 clamps along short frame Edge Clamp width 40 50mm height 30mm A 50 100mm maximum test load front 1200Pa back 1200Pa JW HD108N P Mounte...

Страница 11: ...he screw faces the frame mounting holes D The outer flat washer needs to use M8 A2 70 a stainless steel SUS304 flat washer with an outer diameter of 20 2 mm and a thickness of 1 1 1 2 mm the corresponding stainless steel spring washer thickness is 2 0 0 2mm B The modules are fastened at 8 points according to load requirements or installation requirements Four points on the long side C The tensile st...

Страница 12: ...lectrical contact is formed by penetrating the anodized coating of the aluminum frame and tightening the ground screw together with the star washer to an appropriate torque of 3 7N m A properly sized ground wire 4 16mm2 copper core wire should be selected and mounted under the connecting bolt Place the toothed washers washers and grounding wires in turn and screw the screws into the grounding hole...

Страница 13: ...age of modules shall not be higher than the maximum voltage borne by the system and factors such as the lowest expected temperature shall be considered It is recommended to calculate according to the following formula Maximum system voltage N x Voc x 1 Tcvoc x Tmin 25 Of which N represents the number of modules Voc represents the open circuit voltage of the component Tcvoc represents the temperatu...

Страница 14: ...1 4 If module is damaged glass breakage or scratches on the back glass it is need to be replaced Module must be replaced with same type one Do not touch the live parts of the cables or connectors when replacing modules Use appropriate safety guards insulation tools insulated gloves insulated boots etc when handling modules a The maximum rating of the fuse connected in series is 30A and the module ...

Страница 15: ...g The amount of electricity produced by a solar module is proportional to the amount of light reach on surface of it A dust covered module produces relatively lower power so it is important to keep module clean a The PV module should be cleaned under the irradiance of less than 200W m2 Avoiding cleaning water with great different temperature from air to avoid cracking Hard water needs to be softene...

Страница 16: ...e any questions about technology or claims please contact the installer Please visit http www jolywood cn to contact Jolywood after sales service team Please submit the Customer Feedback Information Form at http www jolywood cn Our technical service representatives will contact you within 5 working days The required username and password will be sent via the Customer Service link Please download t...

Отзывы: