background image

Surface Technology

Oberflächentechnik

14

Unscrewing the handpiece from the micromotor

The handpiece is screwed onto the mircromotor. A hook spanner is used for loosening.

Figure 7.4    Schematic drawing

Quick coupling system joke Rapid-Change for ENESKA 3-2!

•  just pull out the old handpiece an push in the new one

•   modify the motor and handpiece in two steps only: 

connector plug und coupling (order no. 0 007 051 and 0 007 050).

Figure 7.5    Rapid-Change

loosen

screw tight

micromotor

handpiece

Fuse replacement

 

Pull out the mains cable (7.2/3) from the socket.

 The 230 V mains fuse is located behind the cover (7.2/2). Pull out the fuse holder on the rear of the 

unit.

Replace the fuse. The fuse must comply with specifi cation 250 Vac, T1A.

Содержание 0007500

Страница 1: ...Instruction manual ENESKA 3 2 Order No 0 007 500 and 0 007 520...

Страница 2: ...e FMV N Order No 0 001 210 Collets CHC Collets CHG Collets NKM 6 Collets K 253 Collets K 252 Rapid chuck handpiece JIR 310 Order No 0 007 515 DIPROFIL Hand filing machine FPT NR Order No 0 005 203 DIP...

Страница 3: ...S Order No 0 007 506 Micromotor JENK 410S Order No 0 007 505 Connection plug and coupling Order No 0 007 051 and 0 007 050 Rapid Change Foot control FC 64 Order No 0 007 504 Step down gear RG 01 4 1 O...

Страница 4: ...ed The symbols used in the manual have the following meanings Working and operating processes which must be observed to the letter to exclude any risk to persons The illustrations and diagrams are num...

Страница 5: ...ad this instruc tion manual and particularly the safety instructions chapter before starting work This applies especially for personnel who only work with the device occasionally 5 Stop the device imm...

Страница 6: ...appropriately trained personnel If it is not all warranty claims will be forfeited according to the terms of delivery The device may only be used by appropriately trained personnel If it is not all w...

Страница 7: ...ctly the right combination for any requirement and to suit any working use For recommended tools please see the joke catalogue section on Driving motors and handpie ces 1 Control unit NE270 2 Motor ca...

Страница 8: ...000 rpm Output 73 W 76 W max Torque 4 3 N cm2 4 8 N cm2 Vibration level less than 2 5 m s2 when connecting to the micromotor JENK 410S and JIR 310 Noise level less than 80 dB A when connecting to the...

Страница 9: ...ward reverse LED 4 Speed control knob 5 Fixpeed switch 6 Fixpeed LED 7 Mains switch On Off 8 Support adjust the position by swivelling 9 Connection socket B for connection cable 10 Pushbutton connecti...

Страница 10: ...7 1 6 illuminates The rpm now remains constant at the saved speed One speed and one direc tion of rotation can be saved for each motor output which is also retained after switching on the control uni...

Страница 11: ...e see fuse replacement The 230 V fine fuse is loca ted behind the cover Figure 7 1 10 and 7 1 14 The connection socket A or B is selected by pressing the pushbuttons for motor B or A Figure 7 1 12 Loa...

Страница 12: ...speed system to use the micro motor Manual operation Set the rotation speed with the speed control knob 7 1 4 and check the speed on the speed display Select the desired motor by pressing either moto...

Страница 13: ...other In this case turn the shaft of the handpiece until the coupling notches into place Tighten the handpiece firmly with a hook spanner Figure 7 3 Schematic drawing Do not apply any force This could...

Страница 14: ...ull out the old handpiece an push in the new one modify the motor and handpiece in two steps only connector plug und coupling order no 0 007 051 and 0 007 050 Figure 7 5 Rapid Change loosen screw tigh...

Страница 15: ...wever at the saved rpm One speed and one direction of rotation can be saved for each motor output which is also retai ned after switching on the control unit again select the appropriate motor 7 1 14...

Страница 16: ...display and set rotation speed is displayed repeatedly Put the power switch depressing the foot pedal E 1 Overcurrent detection error long time use at a high load shorted cord power line shorted motor...

Страница 17: ...g machine FMD 3 2 Order No 0 005 550 q DIPROFIL mini hand filing machine FPT NR Order No 0 005 203 q Hand filing machine JFMM 3 Order No 0 005 400 q DIPROFIL mini hand filing machine FMR N 5 Order No...

Страница 18: ...ch Tel 49 0 2204 839 0 Fax 49 0 2204 839 60 Mail info joke de Web www joke de Copyright joke Technology GmbH July 2012 All rights reserved for technical modifications inaccuracies and printing errors...

Отзывы: