Connecting the filing handpiece
1. Connect the air supply hose of the pneumatic filing handpiece to the maintenance unit.
2. Set a pressure of 6 bars on the maintenance unit.
The hand-filing machine is ready for operation.
3. Insert the tool in the collet and tighten with the Allen key supplied.
4. The device is switched On and Off by operating the rotary knob.
Oiled compressed air must
NOT
be used in order to guarantee optimum function.
i
Tool receptacles
• The linear and transverse stroke hand-filing machines are only intended for manual use.
• The tool receptacle is designed such as to accommodate tools with a round shaft Ø of up to
3.1 mm and flat tools of up to 4.0 mm high.
Changing the tool
Use the Allen key. Insert tools depending on their dimensions and position as desired.
Tighten the clamping claw and check that the tools are firmly seated.
Usable, reliable tools can be found in the current joke catalogue.
i
Maintenance unit and air connection
The maintenance unit must consist of the following functional units:
• Water and dirt separator
• Pressure gauge
The compressed air needed to drive the compressed air filing machine must be supplied by
means of a maintenance unit.
Optimum function of the compressed air filing machine is guaranteed by using the joke Dryjet
maintenance unit (order no. 0 004 060). Further accessories and the installation package can be
found in the current joke catalogue.
i