Error message Inverter error troubleshooting
[Symptom]
Press start then the console display show “Inverter error“
[Cause]
1. The 7-pin inverter cable is damaged.
2. Inverter is damage.
[Solution]
1.Please check the between Inverter and Inverter cable whether connect is OK, if it
is OK, please replace new inverter cable to test again.
2.Please check the below inverter Default Value place parameter.
(If all parameter is OK, replace the Inverter)
1st level adjustment
parameters:
ACC
8.0 Sec
dEC
5.0 Sec
LSP
1.0 HZ
HSP
125.0 HZ
ItH
7.5 A
Alt
Act
10U
Motor control menu
drC:
Uns
220.0V
Frs
60.0HZ
StA
20%
FLG
20%
UFr
80%
nCr
7.5A
CLI
11.2A
nSL
2.6HZ
SLP
50%
COS
0.80
Application functions
menu FUn:
Tcc
ACt
2C
tCt
LEL
Rrs
LI2
PS2
LIA NO
rSF
NO
rP2
L1
NO
nst
L13
StP
NO
brA
yES
AdC
ACt NO
SFt
Act
HF
SFr 16.0
FLr
NO
dO
ACt nO
Atr
yES
Lsr
tEr
nPL
nEG Pos
bFr
60.0HZ
SCS
nO
FCS
nO
Содержание T8000PRO
Страница 1: ...1 Johnson T8000PRO SERVICE MANUAL...
Страница 3: ...3 SECTION 1 MAINTENANCE PROCEDURE...
Страница 9: ...9 SECTION 2 WIRING DIAGRAM INSTRUCTION...
Страница 12: ...12 CNT8 Console cable...
Страница 13: ...13 CNT6 Inverter cable...
Страница 15: ...15 J2 Right key cable...
Страница 16: ...16 J1 Left key cable...
Страница 17: ...17 J4 Display board cable...
Страница 18: ...18 J8 HR board cable...
Страница 19: ...19 T8000PRO Electrical block diagram for 110V...
Страница 20: ...20 T8000PRO Electrical block diagram for 220V...
Страница 21: ...21 SECTION 3 CONSOLE FUNCTIONAL FLOW DIAGRAM...
Страница 22: ...22 OPERATING T8000PRO MANUAL...
Страница 25: ...25 SECTION 4 Incline power board LED INSTRUCTIONS...
Страница 27: ...27 SECTION 5 TROUBLESHOOTINGS...
Страница 40: ...40 SECTION 5 STEPS FOR SETTING UP THE INVERTER...
Страница 41: ...41...
Страница 42: ...42...
Страница 43: ...43...
Страница 44: ...44...
Страница 45: ...45...
Страница 46: ...46...
Страница 47: ...47...
Страница 48: ...48...
Страница 49: ...49...